3.0
2.5
2.0
1.5
1.0
0.5
0.0
100
Drive with d u /d t filter
A
B
Drive without d u /d t filter
I
Motor cable length
U n
Nominal AC line voltage
Û LL / U n
Relative peak line-to-line voltage
(d u /d t )/ U n
Relative d u /d t value
Note: Û LL and d u /d t values are approximately 20% higher with resistor braking.

Additional note for sine filters

A sine filter also protects the motor insulation system. The peak phase-to-phase
voltage with a sine filter is approximately 1.5 · U
Guidelines for planning the electrical installation 105
A
Û
/U
LL
n
d
u
/
d
t
-
-- - -
-- -
- - - - (1/ µs)
-
U n
200
300
l (m)
5.5
5.0
du/dt
-------------(1/ µs)
U n
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
100
.
n
B
Û
/U
LL
n
200
300
l (m)