done with the pushbutton: Press and hold
EN
the pushbutton for 10 seconds to approve
a new user.
14
Fault messages
The following heater faults are displayed as
fault messages in the ThermoConnect app.
You will find further information in the
operating instructions for the heater.
WARNING
Inspections and repairs on heaters
must only be carried out by trained
personnel.
Fault mes-
Fault
Description
sages
code
Heater
0x06
Overheating lock-out
overheating
has tripped (heater
overheated).
Heater lock-
0x07
Heater lock-out was
out
activated.
Permanent
0x87
Permanent heater
heater lock-
lock-out was activ-
out
ated.
Operating
0x84
Supply voltage is too
voltage too
low. Charge the bat-
low
tery and check car
electrical installation.
10
Fault mes-
Fault
Description
sages
code
Supply
0x04
The operating voltage
voltage too
was higher than the
high
maximum permissible
value for too long.
15
Statutory regulations
governing installation
Regulation
Typ approval number
ECE R10
E17 10 R - 050151
The provisions of these regulations are
binding within the scope of EU Regulation
2018/858 and should also be observed in
countries where there are no special regu-
lations! Failure to follow the installation in-
structions and the notes contained therein
will lead to all liability being refused by
Webasto.
WEEE directive This product
must not be disposed of with
normal household waste.
Dispose of this product according to the
applicable rules and regulations. Informa-
tion about proper disposal is provided by
the municipal authorities, the responsible
household waste recycling centre and/or
your local distribution partner.
The provisions of these regulations are
binding within the scope of EU Regulation
2018/858 and should also be observed in
countries where there are no special regu-
lations! Failure to follow the installation in-
structions and the notes contained therein
will lead to all liability being refused by
Webasto.
16
Declaration of Conformity
CE-Declaration of Conformity and UKCA-
Declaration of Conformity
The ThermoConnect TCon2 was de-
veloped, manufactured, tested and sup-
plied in accordance with the relevant dir-
ectives, regulations and standards for
safety, EMC and environmental compatibil-
ity. Webasto declares that the product
ThermoConnect TCon2 is manufactured
and delivered in accordance with the dir-
ectives and regulations.
The complete CE Declaration of Conformity
and UKCA Declaration of Conformity can
be found in the download area at
https://dealers.webasto.com.
9040092D
Need help?
Do you have a question about the ThermoConnect TCon2 and is the answer not in the manual?