Burner description
2.1
Technical data
Model
Type
Capacity
Output adjustment
Fuel
Combustive air temperature
Electrical supply
Ignition
Flame control
2.2
Firing rate
250°C
150°C
50°C
0
4
Min./Max. natural gas [kW]
2000
Modulating
Natural gas (G 20) - Net calorific value 10 kWh/Nm
Natural gas (G 25) - Net calorific value 8.6 kWh/Nm
Max. 250 °C
230 V
+/-10%
50 Hz
Electrical
Standard (1 stop in 24 hours) FS1
7150
5500
8600
DB 9 SM
46662X
5500 ÷ 9500
3
3
S8871
DB9
kW
9500
Fig. 1