Contents Declaration....................................3 Information and general warnings............................4 Information about the instruction manual........................4 2.1.1 Introduction ..................................4 2.1.2 General dangers ................................4 2.1.3 Danger: live components ..............................4 Guarantee and responsibility ............................5 Guidance for the use of bio fuel blends up to 30% ......................5 2.3.1 Information and general instructions..........................
Page 4
Contents Maintenance ....................................21 Notes on safety for the maintenance..........................21 Maintenance programme ..............................21 9.2.1 Maintenance frequency ..............................21 9.2.2 Maintenance position ..............................21 9.2.3 Checking and cleaning ..............................21 10 Faults / Solutions ..................................23 2902812...
Declaration Declaration Declaration of conformity in accordance with ISO / IEC 17050-1 Manufacturer: RIELLO S.p.A. Address: Via Pilade Riello, 7 37045 Legnago (VR) Product: Kerosene and gas oil burner Model: These products are in compliance with the following Technical Standard:...
Information and general warnings Information and general warnings Information about the instruction manual 2.1.1 Introduction 2.1.3 Danger: live components The instruction manual supplied with the burner: This symbol indicates operations which, if not car- is an integral and essential part of the product and must not ried out correctly, lead to electric shocks with le- be separated from it;...
All components within the hydraulic circuit suitable for manual, operating negligence, incorrect installa- bio fuel use and supplied by Riello will be identified as Bio com- tion and carrying out of non authorised modifica- patible. No warranty is given in relation to the use of components...
Bio fuel delivery. If this is not completed then due to the In no event shall Riello (and its subsidiaries) be liable for any in- hydroscopic nature of Bio fuel, it will effectively clean the...
Safety and prevention Safety and prevention Introduction The burners have been designed and built in compliance with the type and pressure of the fuel, the voltage and frequency of the current regulations and directives, applying the known technical electrical power supply, the minimum and maximum deliveries for rules of safety and envisaging all the potential danger situations.
Bio blend, it will be essential to use flexible oil lines suitable for bio fuel use. Screws and nuts for flange..........No. 4 Please contact Riello for further information. WARNING Screw with two nuts for flange ..........No. 1 Screw of by-pass pump............No. 1 4 pole socket ...............
Technical description of the burner Burner dimensions Flange Burner D5670 Fig. 2 Firing rate The MAXIMUM OUTPUT is chosen from within the diagram area The work point may be found by plotting a vertical line from the (Fig. 3). desired delivery and a horizontal line from the pressure in the combustion chamber.
Installation Installation Notes on safety for the installation After carefully cleaning all around the area where the burner will The installation of the burner must be carried out be installed, and arranging the correct lighting of the environ- by qualified personnel, as indicated in this manual ment, proceed with the installation operations.
The burner hydraulic components and flexible oil lines must burner technical manual). be suitable for bio fuel use (check with Riello if in doubt). If a Bio blend is in use the installer must seek information Riello have carefully chosen the specification of the bio...
Installation Securing the burner to the boiler Put on the flange 1)(Fig. 6) the screw 2) and two nuts 3). It is necessary that the insulating gasket 5)(Fig. 9) is placed between the boiler door and the burner flange. If necessary, the insulating gasket can be modified as shown in Fig.
Bio blend, it will be essential to use flexible oil lines suitable for bio fuel use. WARNING Please contact Riello for further information. It is strongly recommended a periodic check of the pump pressure operation (annually or better every six months, if the burner operation is contin- uous).
Usually the tank is lower than the burner. You are advised to use additional filters on the fuel supply line. Riello recommends a good quality fuel filter at the CAUTION tank (Fig. 11 - Fig. 12) and a secondary filter (60 ...
You are advised to use additional filters on the fuel supply line. Riello recommends a good quality fuel filter at the CAUTION tank (Fig. 13) and a secondary filter (60 for gas oil and 15 for kerosene) are used to protect the burner pump and nozzle from contamination.
Electrical system Electrical system Notes on safety for the electrical wiring The electrical wiring must be carried out with the electrical supply disconnected. Electrical wiring must be carried out by qualified personnel and in compliance with the regulations currently in force in the country of destination.
Electrical system Electrical wiring 230V ~ 50Hz Main switch Fuse T6A TO BE COMPLETED BY THE INSTALLER Hour counter Limit thermostat Safety thermostat Remote lock-out lamp (230V - 0.5A max.), if required 7 pin plug (boiler) N T1 T2 S3 B4 7 pole socket (burner) CARRIED-OUT IN THE FACTORY...
Start-up, calibration and operation of the burner Start-up, calibration and operation of the burner Notes on safety for the first start-up The first start-up of the burner must be carried out Check the correct working of the adjustment, com- by qualified personnel, as indicated in this manual mand and safety devices.
Start-up, calibration and operation of the burner Pump pressure Kerosene fuel Gas oil fuel 8 bar: pressure suitable for kerosene in most cases. For gas oil increase pressure 10 bar: maximum pressure for kerosene. 12 bar: pressure suitable for light oil in most cases. 14 bar: maximum pressure light oil.
Start-up, calibration and operation of the burner It is important to take account of the fact that the air output of the fan differs according to whether the burner has its metal cover fitted or not. WARNING Therefore we recommended to proceed as follows: ...
Page 23
Maintenance Maintenance Notes on safety for the maintenance The periodic maintenance is essential for the good operation, Before carrying out any maintenance, cleaning or checking oper- safety, yield and duration of the burner. ations: It allows you to reduce consumption and polluting emissions and to keep the product in a reliable state over time.
Page 24
In case of use with gas oil containing up to 30% Bio blend, it will be essential to use flexible oil lines suitable for bio fuel use. Please contact Riello for further information. WARNING Fuel tank If water or contamination is present within the fuel tank, it is es- sential that this is removed before the equipment is to be used.
Page 25
Faults / Solutions Faults / Solutions Here below you can find some causes and the possible solutions When lock out lamp lights the burner will attempt to light only after for some problems that could cause a failure to start or incorrect pushing the reset button.