Technical Data Controller - Quincy Compressor QOFT 20 Instruction Book

Table of Contents

Advertisement

9.8

Technical data controller

General
Supply voltage
Type of protection
• Operating temperature
range
• Storage temperature
range
Permissible humidity
Mounting
Digital outputs
Number of outputs
Type
Rated voltage AC
Rated voltage DC
Digital inputs
Number of inputs
Supply by controller
Supply protection
Input protection
Analog inputs
Number of pressure inputs
Number of temperature inputs
78
24 V AC /16 VA 50/60Hz (+40%/-30%)
24 V DC/0.7 A
IP54 (front)
IP21 (back)
• -10°C.....+60°C (14 °F .....140 °F)
• -30°C.....+70°C (-22 °F ......158 °F)
Relative humidity 90%
No condensation
Cabinet door
9 (Q-Control Touch)
Relay (voltage free contacts)
250 V AC / 10 A max.
30 V DC / 10 A max.
10 (Q-Control Touch)
24 V DC
Short circuit protected to ground
Not isolated
2 (Q-Control Touch)
5 (Q-Control Touch)
Instruction book
9829 3199 74