D Service Outputs

POSITION
Program Items
D1
Heater SSR Test
D2
Fill Valve Test
LT (left)
D3
Brew Valve Test
RT (right)
D4
Brew Valve Test
LT (left)
D5
Bypass Valve Test
RT (right)
D6
Brew Valve Test
LT (left)
D7
Brew Basket Lock
Test
RT (right)
D8
Brew Basket Lock
Test
Single series displays right side only Left Valve display is only for twin side brewer.
D12
LCD Brightness
D13
LED Brightness
Go to fetco.com for the latest versions of all information
Test Valves and Heaters; Set screen brightness
Factory set Default
Programming Range
Press button 2 to
Activates heater
test (button 1 stops
Default is 10 sec..
test)
Press button 2 to
Activates valve
test (button 1 stops
Default is 10 sec.
test)
Activates valve
(Press to test)
Default is 10 sec.
Activates valve
(Press to test)
Default is 10 sec.
Activates valve
(Press to test)
Default is 10 sec.
Activates valve
(Press to test)
Default is 10 sec.
Activates Brew
(Press to test)
Activates Brew
(Press to test)
Brightness=90%
Brightness=60%
Increments
Toggle +/-
OFF or ON
Toggle +/-
OFF or ON
Toggle +/-
OFF or ON
Toggle +/-
OFF or ON
Toggle +/-
OFF or ON
Toggle +/-
OFF or ON
Toggle +/-
Basket Lock
OFF or ON
Toggle +/-
Basket Lock
OFF or ON
20-100%
5%
20-100%
5%
User Guide & Operator instructions
Page 9
Notes
Energizes Heater(s)
WARNING!
Service use only.
Press To Test
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Press To Test
Press To Test
Adjust LCD screen
brightness only-Not for
LEDs under buttons
Adjust LED button
brightness only-Not for
the screen display LCD
P214 September 2023