200°F (93°C) inside water tank (at sea level) Full Batch 1gal. CBS-2132 & CBS-2131—1 gal. version 195°F (91°C) ± 5° at sprayhead Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to change by FETCO without notice.
14.0 gal/53 lit E213213 2 X 3.0 kW 200-240 Terminal Block 4.2 – 6.1 21.3—25.5 14.0 gal/53 lit Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice...
Page 4
Dimensions & Utility Connections—Rough-in drawings CBS-2131 3 liter Rough-in CBS-2131—Single station 3 liter airpot version CBS-2132 3 liter Rough-in CBS-2132—Twin station 3 liter airpot version NEMA PLUG CONFIGURATION NEMA 5-15P NEMA 5-20P CBS-2131 1 gallon Rough-in CBS-2131—Single station 1 gallon airpot version...
Here are the key points to consider before installation: Electrical: All FETCO brewers require an electrical ground wire. Installation without grounding is dangerous. Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment. The electrical diagram is located in the Users Guide and online at www.fetco.com.
Page 6
The heating process will start automatically when the tank has filled. 3. Most CBS-2131 equipment is factory equipped with a 120 V cord and plug. Some CBS-2131 and all CBS- 2132 have a terminal block for connecting the incoming power wires. Consult local codes to determine if a cord and plug can be installed on factory supplied terminal block equipment, or if the unit must be hard wired.
Page 7
4. Pre-check will display: "DC voltage calibration for pumps is running…Please wait…Calibration is successfully done”. (15 seconds) 5. The water tank will begin filling. FETCO Home Screen #1 will read “FILLING”. 6. When the water level rises and is sensed by the probe at the top of the tank the heaters will activate 7.
Calibration is successfully done. FETCO home screen will display on completion Batch selection and brew operation menu screens Tap FETCO HOME SCREEN to enter batch selection screen. Tap left or right side batches Hold down batch selector pennant to begin brew.
Page 9
Operator Training Review the operating procedures with whoever will be using the brewer. Pay particular attention to the following areas: 1. Always pre-heat the dispensers before the first use of each day by filling them half way with hot water, and letting them stand for at least 5 minutes.
To brew a single 3 liter coffee batch, using default recipe NOTES FETCO CBS-2130 series equipment is factory calibrated and preloaded with recipes and is ready to brew. Place 13”X5” paper filter in brew basket -FETCO Product # F002 or any 13”X5”...
Page 11
Brewing-shown by touchscreen Brewer screens displayed for brewing NOTES CBS-2131 CBS-2132 “READY SCREEN” Note: there are three “BREW AT Tap screen to display TEMPERATURE DEFINITONS”. The “Brew menus at temperature default routine is shown below. Brew basket sensor Unit displays four enabled.
Programming- operator access programming -The FETCO CBS-2130 brewers have four brew batch menus per side. They are preprogrammed with basic settings that will operate the equipment as purchased. There are two batches each marked “Regular” and two marked “Decaf” -Most operators prefer a full batch and half batch setting for regular and decaf or specialty coffees. These will need to be programmed by the operator -Settings are adjustable and the names can be changed.
Page 13
(See Batch 2-Left) Batch 4 Right ** Batch Copy Copy From Batch L1-L4;R1-R4 Copy To Batch L1-L4;R1-R4 L1 L2? Copy? |_______________ (example) Batch 1&4 cannot be disabled. (CBS-2132); Batch 1 cannot be disabled. (CBS-2131) Batch can be disabled, and removed from display...
Page 14
Programming Factory set Programming Range GENERAL Notes Items Default (display) 200 °F Correction for high Tank Temp. 200°F |______________[]___| altitude below “OFF” allows AUTO Brew at Temp. AUTO SEE NOTE BELOW! |____________[]___| brewing at any ON AUTO temperature. °F • Temperature °F Units of Meas.
Page 15
Programming Factory set Programming Range OTHER Notes Items Default (display) Error Codes • Display Errors (Codes) Chart is below Reset !!Errors must be • Reset Errors (Reset) |_______________[]____| corrected and cleared!! Setup upload Brewer Copy ------------------------------------------------------------------------ • From SD to B. Brewer ---- |________________[]____...
Page 16
Programming Factory set Programming Range OUTPUTS Notes Items Default (display) TEST Runs pump to verify Left Pump • Left Pump Test (Press to test) Press To Test flow. Have container under brewbasket! 0.49 Calibrate Factory or service use • L. Pump Calib ’’...
Brewbasket must Insert brewbasket be in place INSERT Error codes must be BREW cleared! BASKET Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice...
D063 (1 gallon) Airpot ® DESCRIPTION : Dispenser Diagram The FETCO D041 (3 liter) and D063 (1 gallon) airpots are lever type, air pressure evacuated beverage dispenser featuring double-wall, vacuum insulated construction. The hermetically sealed vacuum double-wall construction provides excellent heat or cold retention, while the stainless steel outer and inner liners provide robust durability.
Page 19
Buttons to release the lid. dispenser Locator (if airpot : featured). Swing the lid completely 3 liters (FETCO D041) Align the center of the backwards -or- airpot Drip-Through with 1gallon (FETCO D063) the outlet of the brewbasket.
Page 20
Dispenser Cleaning & Maintenance D041 (3 liter) and D063 (1 gallon) Airpot ® To Clean : Squeeze the Lid Release Carefully remove the Remove the Drip-Through Buttons to release the lid. bellows Cap. Detach the Down-Tube Press the Lid Detach Button Handling the parts gently, and the Spout-Tube.
Page 21