Installation Overview

Building the Serial Ribbon Cable

Appendix A. RTS 1-Port Embedded System Installation

Appendix A. RTS 1-Port Embedded
System Installation
This Appendix only discusses the RTS 1-Port Embedded. See
Installation
on Page 5 for installation procedures for other RTS models.
Installing the RTS 1-Port Embedded system follows these basic steps:
Building the serial ribbon cable.
Mounting the RTS and installing light pipes.
Attaching the serial and network cables.
Applying power to the RTS and verifying installation.
Use the following information to build a DB9 serial
ribbon cable to connect to the RTS 1-Port Embedded
IDC connector (J2).
J2 Header
10-Pin
Socket
RS-232
RS-422
1
CD
Not used Not used
2
TxD
TxD-
3
GND
Not used Not used
4
RTS
TxD+
5
RI
Not used Not used
6
RxD
RxD-
7
DTR
Not used Not used
8
DSR
Not used Not used
9
CTS
RxD+
10
Not connected
9 10
Ribbon Cable
1 2
Hardware
IDC10 1 2 3 4 5 6 7 8 9
DB9M 1 6 2 7 3 8 4 9 5
RS-485
TRX-
TRX+
Not used
Not used
Pin 5 Pin 9
DB9
Male
Pin 6
Pin 1