Continuous Low Level Sensor, 25A101
This sensor kit is for the F4-5 and includes two sensors,
each with a bracket for mounting to the machine and
hardware for attaching the bracket.
E Cable from
Electronic
Enclosure
These sensors are mounted on the ram frame behind
the ADM and light tower.
1. Mount the sensor with the bracket as shown below
and use the hardware included in the kit to attach it.
2. Cables from the electronic enclosure are run
through the cable and hose guide. Look for the
cable marked E coming from the guide and connect
it directly to the low level sensor.
3A3103A
Cable and
Hose Guide
Cables from
the Electronic
Enclosure
3. Adjust the sensor's laser beam to target the
machine's ram tie bar bracket.
4. Repeat these steps for the other sensor. To ensure
accurate readings, mount the sensors so that there
are no obstructions.
Installation