Download Print this page

Cembre HTEPE.DET10 Operation And Maintenance Manual page 7

Hydraulic tool

Advertisement

26
4.2) Oil top up
Every six months check the oil level in the reservoir. If necessary, top up the oil level to the upper lip
of the reservoir and remove all air from the reservoir, see 4.1, points a, b, c, and e, fi nally, complete
with operations h and i.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fl uid.
Ensure that disposal of used oil is in accordance with current legislation.
4.3) Replacement of the automatic coupler
To replace the automatic coupler of the hose or head, proceed as follows:
Remove the old coupler.
Carefully clean the thread to remove old sealant.
Apply Tefl on tape to the thread
Fit the new automatic coupler and tighten to 20 Nm (15 lbf ft).