Weather Station - Davis Instruments Vantage Connect 6620 User Manual

For vantage pro2, vantage pro2 plus, vantage vue and weather envoy
Table of Contents

Advertisement

Power Up Vantage Connect 6621 & 6622
(CDMA & 3G)
Note:
It is important to register your Vantage Connect before powering it up to avoid a delay
in uploading data. If you accidentally power the unit before registering, it will
automatically go to sleep. After 24 hours, it will wake up and check for registration
again. If you already powered up before registering, remove power from the Vantage
Connect, register, then repower.
1. If using cabled Vantage Connect (6621C or 6622G) with a cabled ISS, remove
the plug from one of the holes in the bottom of the shelter. Run the ISS cable
up through the hole. Outside the shelter, wrap a split grommet around the cable
and push the grommet securely into the hole. Plug the cable into the ISS cable
jack.
2. For both wireless and cabled versions, plug the main power cable back into the
jack. You should hear two beeps.
Vantage Connect will now begin to acquire both the radio signal from the weather
station as well as the cell signal. As this is occurring, you may see the lights go on
an off or blink, but after about a minute, the lights will begin to indicate the status
of your connections. You will be able to use the lights to verify connection or
troubleshoot connection problems by watching the LED lights.
The lights flash when Vantage Connect is searching for a signal from the weather
station (upper LED) or a cell signal (lower LEDs). Once the signal is detected, all
four cell status lights will turn solid and stay on for a few minutes, indicating
success. It can take several minutes to acquire all signals.
See Vantage Connect 6621 & 6622 (CDMA & 3G): Normal and Error LEDs on
page 16 to ascertain what error is being indicated and to report to Tech Support.
Status LEDs
Status LED
on/off
button

Weather Station

Cell Status:
1, 2, 3, 4
9