Davis Instruments Rain Collector II Installation Manual

Davis rain collector ii weather-accessories: install guide
Hide thumbs Also See for Rain Collector II:

Advertisement

Rain Collector II
Installation manual
This instruction manual takes you step-by-step through the procedures required to
install the Rain Collector II. The Rain Collector II is designed for use with any of
Davis' weather stations (with the exception of the Perception II
can display rainfall in either inches or millimeters. Instructions for displaying rainfall
on the Weather Wizard III
Components
The Rain Collector II includes the following components. Please make sure you have
all listed components before continuing.
•Rain Collector with Cable — The rain collector comes with the cone attached to the
base and has a 40' (12m) cable.
•Four #8 x 3/4" Screws
•Debris Screen — This screen is placed into the rain collector cone to help prevent
debris from clogging the funnel hole.
•Metric Rain Adapter — This adapter adds weight to the tipping mechanism, adjusting
it to tip for every 0.2 mm of rainfall instead of every 0.01".
®
®
and Weather Monitor II
are also included in this manual.
®
Station). Each station

Advertisement

Table of Contents
loading

Summary of Contents for Davis Instruments Rain Collector II

  • Page 1 Installation manual This instruction manual takes you step-by-step through the procedures required to install the Rain Collector II. The Rain Collector II is designed for use with any of Davis’ weather stations (with the exception of the Perception II can display rainfall in either inches or millimeters. Instructions for displaying rainfall ®...
  • Page 2 Rain Collector Internal Components The illustration below shows the internal components of the rain collector, many of which are referenced in this manual. Rain Collector Internal Components...
  • Page 3: Tools And Materials Needed

    Tools and Materials Needed You may need some of the following tools and materials to install the rain collector. •Drill with 3/32" (2 mm) drill bit •Medium Phillips Screwdriver •3/16" (or 5 mm) Wrench •Cable Clips or Weather-Resistant Cable Ties with screw holes or other means for mount- •Bubble Level (standard versions only) Insert the Optional Metric Measurement Adapter The rain collector tipping bucket mechanism contains a standard measurement weight...
  • Page 4 5. Slide the magnet, with the exposed end of the magnet first, into the open slot of the metric measurement adapter. Separate magnet from one end cap Insert magnet with other end cap into metric measurement 6. Insert the metric measurement adapter between the arms of the tipping bucket, with solid side of the metric measurement facing up.
  • Page 5 9 for instructions. Testing the Rain Collector II Before installing the Rain Collector II, test the unit. If you are replacing a rain collector you previously installed, make a note of the total rainfall amount displayed. You may want to reenter this amount after you test the rain collector.
  • Page 6: Installing The Rain Collector

    Note: Climbing on your roof may be hazardous. If you are uneasy about installing your unit please have a qual- ified professional complete the installation. Davis specifically disclaims any liability for injury or loss resulting from the installation or use of the Rain Collector II.
  • Page 7 Keep the following in mind when choosing a location for your rain collector: •You must mount the Rain Collector II on a level surface. To make sure the surface is level, use a bubble level or pour water into the T-shaped leveling trough in the collector base and observe the surface of the water to ensure that the collector is level.
  • Page 8 Note: Modify both adjustment screws by the same amount. To check the accuracy of the rain collector, compare the Davis Rain Collector with a tube type rain gauge. Use a rain gauge with an aperture of at least 4 inches. Any smaller and the readings obtained may not be accurate.
  • Page 9 Maintaining the Rain Collector II For greatest accuracy, you should thoroughly clean the Rain Collector II at least once or twice a year. 1. Disconnect the rain collector cable from the junction box. 2. Separate the cone from the base.
  • Page 10: Standard Setting

    Metric Setting When using the 0.2 mm setting of the Rain Collector II with an older model station, note that the station stores rainfall amounts in 0.2 mm increments but displays amounts rounded to the nearest whole millimeter.
  • Page 11: Troubleshooting Guide

    •Rainfall amount shown on console has a small error. • Make sure the rain collector is mounted on a level surface. Use the adjustment screws (see “Adjusting the Rain Collector II” on page 11) to adjust the rain collec- tor’s sensitivity, if necessary.
  • Page 12: Contacting Davis Technical Support

    If you have any questions, or encounter problems installing or operating your Vantage Pro2 weather station, please contact Davis Technical Support. We’ll be glad to help. (510) 732-7814 — Monday - Friday, 7:00 a.m. - 5:30 p.m. Pacific Time. Sorry, we are unable to accept collect calls.
  • Page 13: Specifications

    Weight ......2 lbs. 3 oz. (1 kg) Console Data These specifications apply to sensor output as converted by Davis Instruments weather station consoles.
  • Page 14 Extending Cable Runs Notes...
  • Page 15 Extending Cable Runs Notes...
  • Page 16 Rain Collector II Rev B Manual (10/21/05) This product complies with the essential protection requirements of the EC EMC Directive 89/336/EC. Copyright © 2004 Davis Instruments Corp. All rights reserved. 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. 510-732-9229 • Fax: 510-732-9188...

This manual is also suitable for:

7852

Table of Contents