Section 4 - Specifications; Features And Benefits; Arc Controls; Serial Number And Rating Label Location - Miller XMT 450 CV Owner's Manual

With arcreach
Hide thumbs Also See for XMT 450 CV:
Table of Contents

Advertisement

4-1.

Features And Benefits

LVC
Line Voltage Compensation is circuitry that keeps the power source output constant regardless of input power fluctuation.
Wind Tunnel Technology
circulates air over components that require cooling, not over electronic circuitry, which reduces contaminants and im-
proves reliability in harsh welding environments.
Fan-On-Demand
cooling system operates only when needed, reducing noise, energy use and the amount of contaminants pulled through the
machine.
Thermal Overload Protection automatically shuts down the unit, only when necessary to prevent damage to internal components if the duty
cycle is exceeded or air flow and cooling are restricted (see Section 4-9).
Auto Remote Sense enables the unit to automatically sense the connection of a remote control. Operation of the remote control is dependent
on the Mode Switch Setting (see Section 6-2).
Lift-Arc
®
TIG starts provide a contamination free weld without the use of high frequency in the Lift-Arc TIG Welding Mode (see Section 7-2).
ArcReach
Remote Controlallows remote control of various functions of the power source by an ArcReach compatible wire feeder or remote
®
control device, without the use of a control cable (see Section 6-3). Operation of the ArcReach feature is dependent on the Mode Switch Setting
(See section pertaining to process being used).
Low OCV OperationThis unit can be configured to provide low Open Circuit Voltage (OCV) (see Section 9-3).
4-2.

Arc Controls

Arc Control in Stick Mode allows the arc characteristics, soft versus stiff, to be changed for specific applications and electrodes in Stick Weld-
ing Mode (see Section 9-2).
Arc Control in Wire Mode influences the arc stiffness, bead width and appearance, and puddle fluidity in MIG and V-Sense Feeder Welding
Modes (see Section 8-2 and 8-4).
Programmable Hot Start Time allows the start amperage time to be changed for Stick Welding Modes. This helps eliminate electrode sticking
during arc initiation (see Section 9-2).
4-3.

Serial Number And Rating Label Location

The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements
and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-4.

Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula
4-5.

Information About Default Weld Parameters And Settings

NOTICE – Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical
welding parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are
for reference purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriate-
ness of all parameters and settings should be evaluated and modified by the end user as necessary based upon application-specific require-
ments. The end user is solely responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld
parameters and settings, and ultimate quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warran-
ties including any implied warranty of fitness for a particular purpose.
4-6.

Unit Specifications

Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-8 thru 5-9 for information on
connecting input power.
This equipment will deliver rated output at an ambient air temperature up to 104°F (40°C).
Rated Weld-
Input Power
ing Output
450 A @ 38
Volts DC,
Three-Phase
100% Duty
Cycle
*While idling with fan on
SECTION 4 – SPECIFICATIONS
and are incorporated by reference herein.
Amperage
Voltage Range
Range
15 - 600
10 - 38
Amperes In-
put At Rated
Max. Open-
Load Output
Circuit Volt-
50/60 Hz,
age DC
Three-Phase
400V
31.0
87
(0.15*)
KVA
KW
400V
400V
21.4
18.5
(0.1*)
(0.06*)
OM-292663 Page 13