Electrical Connections - Sears Kenmore 73611 Use, Care, Safety Manual

Table of Contents

Advertisement

1. Install
a manual
gas line shut-off
valve in the gas
line in an easily
accessed
location
outside
of the
range_ Make
sure
everyone
operating
the
range
knows
where and how to shut off the gas supply to
the range.
2. Instalt male 1/2" flare union adapter
to the 1/2" NPT
internal
thread
elbow at inlet of pressure
regulator.
On models
equipped
with
dual
burners,
install
the
male
pipe thread
end of the !/2"
flare union
adapter
to the 1/2" NPT internal
thread
at inlet of
pressure
regulator
Use a backup
wrench
on the
regulator
fitting to avoid damage
When
installing
the range from the front, remove
the
90 ° elbow for easier installation
3. Install male
1/2" or 3/4" flare union adapter
to the
NPT internal
thread
of the manual
shut-off
valve,
taking
care to back-up
the shut-off
valve to keep it
from turning
4. Connect
flexible
metal appliance
connector
to the
adapter
on the range_ Position
range to permit con-
nection
at the shut-off
valve.
5. When all connections
have been made, make sure
all range controls
are in the off position and turn on
the main gas supply valve.
Use a liquid leak detec-
tor at a!l joints and connections
to check for leaks in
the system.
CAUTION:
DO NOT USE A FLAME
TO CHECK
FOR GAS LEAKS.
When
using test pressures
greater
than 1/2 psig to
pressure
test the gas supply system
of the residence,
disconnect
the
range
and individual
shut-off
valve
from
the gas supply
piping.
When
using
test pres-
sures of 1/2 psig or less to test the gas supply
sys-
tem,
simply
isolate
the range
from the gas supply
system
by closing the individual
shut-off valve.
Step
3
Electrical Connections
Electrical
Requirements
120-volt,
60 Hertz, properly
grounded
branch
circuit
protected
by a 15-amp
or 20-amp
circuit
breaker
or
time delay fuse
Extension
Cord Cautions
Because
of potential
safety hazards
associated
with
certain
conditions,
we strongly
recommend
against
the use of an extension
cord° However,
if you still elect
to use an extension
cord, it is absolutely
necessary
that it be a UL-listed,
3-wire grounding-type
appliance
extension
cord and that the current
carrying
rating of
the cord in amperes
be equivalent
to, or greater
than,
the branch circuit rating°
Grounding--IMPORTANT
(Please
read carefully)
FOR PERSONAL
SAFETY, THIS APPLIANCE
MUST
BE PROPERLY
GROUNDED°
The power
cord of this appliance
is equipped
with a
three-prong
(grounding)
plug which mates with a stan-
dard three-prong
grounding
wall receptacle
to mini-
mize the possibility
of electric
shock
hazard
from this
appliance
The
customer
should
have the wall receptacle
and circuit checked
by a
qualified
electrician
to
make sure the recepta-
cle is properly
grounded
Where
a standard
two-
prong wall receptacle
is
encountered,
it is the
PREFERRED
METHOD
ENSURE PROPER
GROUND EXISTS
BEFORE USE
personal
responsibility
and obligation
of the customer
to have it replaced
with a properly
grounded
three-
prong wall receptacle
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR
REMOVE
THE THIRD
(GROUND)
PRONG
FROM
THE POWER
CORD.
(continued next page)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kenmore 73618Kenmore 73619Kenmore 73915Kenmore 73919

Table of Contents