If You Cannot Mount The Logic Analyzer File System; If You Cannot Access The File System Via Ftp - HP 1670A Series User Manual

Logic analyzers
Table of Contents

Advertisement

Troubleshooting
If you cannot mount the logic analyzer file system
If
you cannot mount the logic analyzer file system
If
you get a "device busy" message:
D Make sure that another user
is
not already accessing the file system as
the control user or connected to the conunand parser socket.
If
you get a "stale NFS file handle" message:
D Unmount the file system and
try
mounting again. The likely cause of
this
error
is
turning off power to the logic analyzer before urnnounting.
If
you get a "server not responding" message:
D If the power to the logic analyzer was just turned on, make sure that you
wait 15 seconds after the Analyzer Configuration menu
is
displayed
before attempting the mount.
D Verify the LAN connection between your computer and the logic
analyzer. Refer
to
"If you cannot connect to the logic analyzer" earlier in
this
section.
If
you cannot access the file system via ftp
If
you get a "connection refused" message:
D If the power to the logic analyzer was just turned on, make sure that you
wait 15 seconds after the Analyzer Configuration menu
is
displayed
before attempting the connection.
If
you get a "connection timed out" message:
D Verify the LAN connection between your computer and the logic
analyzer. Refer
to
"If you cannot connect to the logic analyzer" earlier in
this
section.
7-22

Advertisement

Table of Contents
loading

This manual is also suitable for:

1660cs series1660c series