Example
Retrieving and Restoring Data
To restore configurations
To restore configurations
1 Access the logic analyzer's file system as the control user.
Refer to the chapter "Accessing the Logic Analyzer File System".
2 Copy the
setup. raw
file to the appropriate directory.
For system configurations, this would be the
\system
directory. For
analyzer configurations, this would be the
\slot_a
directory. For
oscilloscope configurations, it would be the \ s
lot_b
directory. If you copy
a configuration file to a different directory than it came from, the analyzer
will
not know how to interpret it.
Restoring an analyzer configuration
Suppose you want to load a configuration file called "486_bus" from your local
computer into the logic analyzer's analyzer. The analyzer is always in slot A
The logic analyzer is mounted on your network as disk drive
L : .
To load the configuration file, at the MS-DOS prompt enter:
copy 486_bus L:\slot_a\setup.raw
If
your computer is
running
the UNIX operating system, you might use the
cp
command. In an MS Windows environment, you can use File Manager.