Huawei SUN2000-111KTL-NHM0 User Manual page 134

Hide thumbs Also See for SUN2000-111KTL-NHM0:
Table of Contents

Advertisement

SUN2000-111KTL-NHM0
User Manual
Output
Item
Rated active power
Maximum apparent power
Maximum active power (cosφ = 1)
Rated output voltage
line voltage)
Rated output current
Rated grid frequency
Maximum output current
Power factor
Maximum total harmonic distortion
(rated power)
Note a: The rated output voltage is determined by Grid code, which can be set
on the SUN2000 app, SmartLogger, or NMS.
Protection
Item
Input DC switch
Anti-islanding protection
Output overcurrent protection
Input reverse connection protection
PV string fault detection
DC surge protection
AC surge protection
Insulation resistance detection
Residue current monitoring (RCMU)
Overvoltage category
Issue 09 (2023-12-18)
a
(phase voltage/
Copyright © Huawei Technologies Co., Ltd.
10 Technical Specifications
SUN2000-111KTL-INHM0
111.1 kW
125 kVA
111.1 kW
242 V/420 V,
254 V/440 V and 277 V/480 V, 3W+PE
152.8 A (420 V), 145.8 A (440 V),
133.7 A (480 V)
50 Hz/60 Hz
171.9 A (420 V), 164.1 A (440 V),
150.4 A (480 V)
0.8 leading and 0.8 lagging
< 3%
SUN2000-111KTL-NHM0
Supported
Supported
Supported
Supported
Supported
Type II
Type II
Supported
Supported
PV II/AC III
126