CLEARANCE DIMENSIONS

INSTALLATION ADJACENT TO KITCHEN
CABINETS
This range may be installed directly adjacent to existing
countertop high cabinets (36" or 91.5 cm from the floor).
For the best look, the worktop should be level with the
cabinet countertop. This can be accomplished by raising
the unit using the adjustment spindles on the legs.
CAUTION
The range CANNOT be installed directly
adjacent to kitchen walls, tall cabinets, tall
appliances, or other vertical surfaces above
36" (91.4 cm) high. The minimum side
clearance in such cases is 6" (15.2 cm).
Wall cabinets with minimum side clearance must be
installed 18" (45.7 cm) above the countertop with
countertop height between 35 ½" (90.2 cm) and 37 ¼"
(94.6 cm). The maximum depth of wall cabinets above the
range shall be 13" (33.0 cm).

CABINET

A
48"(121.9 cm)
B
36" (91.5 cm) hood with combustible materials
C
13" (33.0 cm)
D
18" (45.7 cm)
E
35" 1/2 (90.2 cm) / 37" ¼ (94.6 cm)
F
6" (15.2 cm)
G
6" (15.2 cm)
D
F
E
L
If installing toekick, verify that the sum of the cut out areas
equal the recommended ventilation (L)
48" area 51 ½ sq. inches (33107 mm
14
B
A
C
2
).

METAL HOOD

A
48"(121.9 cm)
B
25 1/2"(65 cm) and 31 1/2" (80 cm)
C
13" (33.0 cm)
D
18" (45.7 cm)
E
35" 1/2 (90.2 cm) / 37" 1/4 (94.6 cm)
F
6" (15.2 cm)
G
6" (15.2 cm)
H
1" 9/16 (4 cm)
Shaded area behind range indicates minimum clearance to
combustible surfaces, combustible materials cannot be
located within this area. 12" (305 mm) min. to combustible
surface with Flush Island Trim.
For Flush Island installations, counter surface should have
a cantilever edge meeting the back section of the Flush
Island Trim accessory. As defined in the "National Fuel Gas
Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of
the ANSI Z21.1 scope and are not certified by CSA.
Clearances of less than 6" (15,2 cm) must be approved by
the local codes and/or by the local authority having
jurisdiction.
Fig. 3