Start-Stop Or Continuous Operation - Carrier Vector 8100 Operator's Manual

Trailer refrigeration unit
Table of Contents

Advertisement

11. Start-Stop or Continuous Operation

Start-Stop is provided to reduce power consumption. This feature allows full
automatic control of unit shut down and restart by monitoring compartment
temperature and battery charge condition. The main function of Start-Stop
Operation is to turn off the refrigeration system near setpoint to provide an
efficient temperature control system and to initiate a restart sequence after
certain conditions are met.
1
2
1. With the system powered up (START/RUN-OFF switch in the START/
RUN position), press the START-STOP/CONTINUOUS key until the
desired operation (Start/Stop or Continuous) is highlighted.
2. "START/STOP MODE SELECTED" or "CONTINUOUS RUN MODE
SELECTED" will be displayed in the MessageCenter for 10 seconds.
3. The operation indication in the status bar will no longer be highlighted. The
unit is now running in the displayed mode.
If "CONTINUOUS LOCKED" or "START/STOP LOCKED" is
displayed, the system is currently locked into the displayed mode
of operation and cannot be changed using the "START/STOP -
CONTINUOUS" key.
START/STOP
ELECTRIC
34
.3 34
BOX TEMPERATURE
START/STOP MODE SELECTED
NOTE
19
COOL
o
o
F
SETPOINT
F
62-11784

Advertisement

Table of Contents
loading

Table of Contents