IntelliSet™

Products carried or stored in a refrigerated compartment require a multitude
of refrigerant unit settings that must be checked and, if required, reset each
time a new product is loaded. The APX Control System offers the settings
necessary to meet these requirements. IntelliSet is a feature that allows pre-
selection and naming of the necessary settings for over 40 different products.
The operator may then call up the settings by simply selecting the assigned
IntelliSet name.
For example: a load of apples may require continuous operation at 35°F
(1.7°C) with a defrost every three hours while a load of cheese may require
the same operation with setpoints ranging from 35°F to 42°F (1.7°C to 5.6°C)
and a load of ice cream requires start-stop operation at -22°F (-30°C) with
defrost at 12-hour intervals. The settings required for each product may be
entered into the system and locked so that they cannot be changed, and they
can be given an appropriate name. In the case of cheese, the range of
setpoints may be locked, leaving the operator the ability to change the
setpoint within the locked range.
When a load of apples is going to be picked up, the operator simply selects
"APPLES" from the IntelliSet menu. For cheese, "CHEESE" is selected and
the setpoint reset as required. For ice cream, "ICE CREAM" is selected. With
each selection, the system automatically re-programs the settings to provide
the best temperature control and performance for that particular product.
The above settings are examples of possible settings. Units
leave the factory with default IntelliSets. However, most
customers develop their own set.
An IntelliSet may be pre-programmed as "IntelliSleep" which allows Sleep
mode to be entered by simply changing to that IntelliSet. Range Protect may
be applied to any IntelliSet. Range Protect offers increased energy savings
over normal Start-Stop Operation for commodities that can use less restrictive
temperature control.
1. With the system powered up (START/RUN-OFF switch in the START/RUN
position) and the default screen displayed, press the "=" key.
NOTE
11
62-11784