2-13.
Figure 2-2 shows the available power cords,
which may be used in various countries including
the
standard
power
cord
fumished
with
the in-
strument. HP Part number, applicable standards for
power plug, power cord color, electrical character-
istics
and
countries
using each
power
cord are
listed in the figure. If assistance is needed for se-
lecting
the correct
power
cable, contact
nearest
Hewlett-Packard office.
2-14.
interconnections.
2-15.
When
an
external
bias is applied to the
sample
capacitor
through
DC
BIAS
input con-
nectors on the 4262A rear panel, both plus and
minus sides of the external power supply should be
connected
to the plus
and
minus sides of the
..4262A EXT DC BIAS connector, respectively.
CAUTION
THE MAINS PLUG
MUST BE IN-
SERTED
BEFORE
EXTERNAL
CONNECTIONS
ARE
MADE
TO
MEASURING
AND/OR
CON-
TROL CIRCUITS.
2-16.
Operating Environment.
2-17.
Temperature.
The instrument may
be op-
erated in temperatures from 0°C to +55°C.
2-18.
Humidity. The instrument may be operated
in environments
with relative humidities to 95%
to 40°C.
However,
the instrument
should
be
protected from temperature extremes which cause
condensation within the instrument.
2-19.
Installation instructions.
2-20.
The HP Model 4262A can be operated on
the bench or in a rack mount. The 4262A is ready
for bench operation as shipped from the factory.
For bench operation a two-leg instrument stand is
used.
For use, the instrument
stands are de-
signed to be pulled towards the front of instrument.
2-21.
Installation of Options 907, 908 and 909.
2-22.
The 4262A can be installed in a rack and
be
operated
as a component
of a measurement
system. Rack mounting information for the 4262A
is presented in Figure 2-3.
Section II
Paragraphs 2-13 to 2-28
2-23.
STORAGE
AND SHIPMENT.
2-24.
Environment.
2-25.
The instrument may be stored or shipped
in environments within the following limits:
Temperature...... -40°C to +75°C
Humidity.
6 dca dS es
to 95%
Altitude.
#222
322% 50,000ft
The instrument should be protected from temper-
ature
extremes
which
cause
condensation
inside
the instrument.
2-26.
Packaging.
2-27.
Original
Packaging.
Containers
and mat-
‚erials identical
to. those used in factory packaging
_
are available
through
Hewlett-Packard
offices. If
the
instrument
is being
returned
to Hewlett-
Packard for servicing, attach a tag indicating the
type of service required, return
address, model
number,
and
full serial number.
Also mark
the
container FRAGILE
to assure careful handling. In
any correspondence,
refer to the instrument by
model number and full serial number.
2-28.
Other Packaging. The following general in-
structions should be used for re-packing with com-
mercially available materials:
a. Wrap instrument in heavy paper or plastic. If
shipping to Hewlett-Packard office or service
center, attach
tag indicating type of service
required, return address, model number, and
full serial number.
b. Use strong shipping container. A double-wall
carton made of 350 pound test material is
adequate.
0
. Use enough shock absorbing material (3 to 4
inch layer) around all sides of instrument to
provide firm cushion and prevent movement
inside container. Protect control panel with
cardboard.
d. Seal shipping container securely.
e. Mark shipping container FRAGILE to ensure
careful handling.
f. In any correspondence, refer to instrument by
model number and full serial number.
2-3