INFORMATION:
6
Press the button for 3 seconds to progress reset the management port
IP and admin's password immediately. The default settings are:
 Reset Management Port IP address to DHCP, and then fix IP address:
169.254.1.234/16. It is recommended to confirm the IP address
obtained by DHCP through the optional USB LCM.
 Reset admin's Password to 1234.
7
Console cable (NULL modem cable) to connect from console port of the
storage system to a RS 232 port on the management PC. The console
settings are on the following: Baud rate: 115,200, 8 data bit, no parity, 1
stop bit, and no flow control; terminal Type: vt100.
8
XCubeSAN series supports traditional UPS via a serial port and network
UPS via SNMP. If using the UPS with a serial port, connect the system to
the UPS via the included cable for communication. (The cable plugs into
the serial cable that comes with the UPS.) Then set up the shutdown
values for when the power goes out.
For a greater understanding of the related color and the behavior of the controller module,
please refer to the chapter 5.2,
chapter.
6
Reset Button
Console Port
(3.5mm jack to RS232)
8
Service Port
(UPS)
Management Port
USB Port 1
USB Port 2
10GbE iSCSI
Port 1
(RJ45)
10GbE iSCSI
Port 2
(RJ45)
12Gb/s SAS Wide Port 1
12Gb/s SAS Wide Port 2
Rear Panel
section in the Descriptions of LEDs and Buttons
7
(SFF8644)
(SFF8644)
System Components Overview