7.3 Basic circuit diagram for part winding start with standard motor
0
QA1
L1
L2
D
GB
F
E
I
Ru
Fig. 12
BP2
High pressure safety monitor
Safety chain (high/low pressure monitoring)
BP3
BT1
Cold conductor (PTC sensor) motor winding
BT2
Thermal protection thermostat
BT3
Oil temperature sensor (PTC sensor)
BT4
Release switch (thermostat)
DELTA-P II Oil differential pressure sensor DELTA-P II (accessories)
EB1
Oil sump heater
EC1
Compressor motor
Οnderung
Datum
18 | AQ451337713574en-000401
1
FC1.1
60%
I>
I>
I>
QA2
L3 N PE
Anschlußkasten Verdichter
Compressor terminal box
Datum
20.02.2009
Bearb.
bauknecht
Gepr.
03.11.2020
Name
Norm
2
FC1.2
40%
I>
I>
QA3
PE
EC1
1U1
2U1
M
1V1
2V1
Y/YY
1W1
2W1
BT1
Urspr.
3
FC2
I>
SF1
FC1.1
FC1.2
12
14
11
L
N
B1 B2
INT69
Ers. f.
© Danfoss | Climate Solutions | 2023.10