4.6
Securing the burner to the boiler
Detach the combustion head from the burner, (Fig. 11):
disconnect the oil pipes by unscrewing the two connectors 6);
loosen the 4 screws 3) and remove the cover 1);
disengage the swivel coupling 14) from the graduated sector;
remove the screws 2) from the slide bars 5);
remove the 2 screws 4) and pull the burner back on slide bars
5) by about 4";
D11001
4.7
Electrode position
Make sure that the electrodes are positioned as
shown in Fig. 12.
WARNING
20036932
Installation
install the extension bars 31)(Fig. 3, page 10) and re-screw
the screws 2) including the safety plate 15);
disconnect the electrode wires and then pull the burner com-
pletely off the slide bars.
2
15
5
3
1
14
20
GB
4
9
4"
8
13
6
7
D10108
12
11
10
L
Fig. 11
3/ 32"
Fig. 12