Securing The Burner To The Boiler; Hinge Installation; Positioning The Probe - Electrode - Riello 40 FS5 Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

4.6

Securing the burner to the boiler

Provide an adequate lifting system of the burner.
4.6.1

Hinge installation

Install the hinge 4), supplied as standard, as shown in Fig. 8.
S7392
4.7

Positioning the probe - electrode

Do not turn the ignition electrode but leave it as
shown in Fig. 10.
if the ignition electrode is put near the ionisation
WARNING
probe, the flame control amplifier might be dam-
aged.
B
Probe
D5033
4
A
Probe
Installation
 Separate the combustion head assembly from the burner
body by removing nut 1) and removing the group A)(Fig. 9).
 Fix the group B)(Fig. 9) to the boiler plate 2), inserting the
supplied insulating gasket 3).
The seal between burner and boiler must be
airtight.
WARNING
Fig. 8
A
Place the ceramic part of the electrode A) against
the diffuser disc B)(Fig. 10).
WARNING
Diffuser
Electrode
2.0
13
GB
1
3
D5067
B
Electrode
2.5 - 3.5 mm
Fig. 10
20065652
2
Fig. 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

566 m

Table of Contents