Combustion Head Setting; Burner Refitting - Riello RLS 70/EV Installation, Use And Maintenance Instructions

Dual fuel light oil/gas burners
Table of Contents

Advertisement

4.9

Combustion head setting

The setting of the combustion head depends exclusively on the
maximum delivery of the burner.
Turn screw 6)(Fig. 18) until the notch shown in diagram (Fig. 19) is
level with the front surface of flange 5)(Fig. 18).
Example RLS 100/EV:
maximum burner delivery = 23.1 GPH.
If diagram (Fig. 19) is consulted it is clear that for this delivery, the
combustion head must be adjusted using notch 3, as shown in
(Fig. 18).
In case of high altitude site, head setting must refer to the "correct-
ed capacity" according precedure described at page 11.

4.10 Burner refitting

 Refit the burner to the slide bars 3)(Fig. 20) at approximately
4" from the sleeve 4) - burner positioned as shown in (Fig. 11,
page 20) - insert the ignition electrode cables.
 Remove the extension bars 31)(Fig. 3, page 10).
 Slide the burner up to the sleeve so that it is positioned as
shown in Fig. 20;
 refit screws 2)(Fig. 20) on slide bars 3) including the safety
plate 15)(Fig. 11, page 20);
 secure the burner to the sleeve by tightening screws 1);
 connect the oil pipes again by screwing on the two connectors
6)(Fig. 11, page 20).
 connect the swivel coupling 7) from the graduate sector.
When fitting the burner on the two slide bars, it is
advisable to gently draw out the high tension cables
until they are slightly stretched.
WARNING
Installation
2
D11171
23
GB
20066614
Burner max. output
1
3
6
Fig. 18
20066615
Fig. 19
4
5
7
Fig. 20
20036932

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rls 100/evC9335700C9335710C933570120065636

Table of Contents