Assignment Of The Bus Module Ip Address; Displaying The Bus Module Ip Address; Deleting Ip Settings And Device Names - Fronius RI FB PRO/i Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Assignment of the Bus Module IP Address

Assignment of
the Bus Module
IP Address
Displaying the
The IP address of the bus module assigned by the master can be viewed on the
Bus Module IP
website of the power source. Proceed as follows in order to do this.
Address
Note down the IP address of the power source used:
1
2
3
4
Access website of the power source in the internet browser:
5
6
7
Display IP address of the bus module:
8
9
Deleting IP Set-
The two options listed below are available for the deletion of the IP settings and
tings and Device
the device name.
Names
Using the DIP switch:
1
2
On the power source website:
1
On the power source control panel, select "Presets"
On the power source control panel, select "System"
On the power source control panel, select "Information"
Note down the displayed IP address (example: 10.5.72.13)
Connect computer with the network of the power source
Enter the IP address of the power source in the search bar of the Internet
browser and confirm
Enter standard user name (admin) and password (admin)
-
The website of the power source is displayed
On the power source website, select the "RI FB PRO/i" tab
The current IP address is displayed under the "Fieldbus configuration" point.
For example: 192.168.0.12
Switch all positions on the DIP switch to OFF (position 1–6)
Restart interface
(disconnect power supply and then reconnect again)
Select the "RI FB PRO/i" tab on the power source website
In the case of ProfiNet, the assign-
ment of the IP address, the subnet
mask, and the default gateway is carri-
ed out by the master. A device name is
also assigned to the interface by the
master.
Therefore the IP address cannot be set
via the DIP switch.
The communication takes place via the
IP address assigned by the master.