Set the Process Data Width of the Bus Module
Setting the pro-
Note down the IP address of the power source used:
cess data width
1
of the bus modu-
2
le
3
4
Open website of the power source in the internet browser:
5
6
7
Set the process data width of the bus module:
8
9
10
On the power source control panel, select "Defaults"
On the power source control panel, select "System"
On the power source control panel, select "Information"
Note down the displayed IP address (example: 10.5.72.13)
Connect the computer to the network of the power source
Enter the IP address of the power source in the search bar of the internet
browser and confirm
Enter the standard user name (admin) and password (admin)
-
The website of the power source is displayed
On the power source website, select the "RI FB PRO/i" tab
Under "Process data", select the desired process data configuration
Select "Save"
-
The field bus connection is restarted and the configuration is applied