General Information. P6; Introduction. P6 - BeaconMedaes MAT-S Installation, Operation And Maintenance Instructions

Medical gas supply system cylinder manifold system and manifold changeover system
Table of Contents

Advertisement

Medical Gas Supply System
1.
General Information.
Figure 1 - Manifold Changeover System (MAT-S).
22
23
26
7
9
6
3
11
4
13
16
5
NOTE - Isolation valves item 8, 12 and 14 are shown in
their open position, this is typically the normal operating
condition for the manual valves.
4109992459.00
24
28
21
27
19
20
1.1
Introduction.
Intended Use
The BeaconMedaes Medical Gas Supply System,
mainly consists of cylinder manifold system, manifold
changeover system, header & pigtails and other necessary
components, is intended to work in conjunction with
other devices within the medical gas pipeline system
(MGPS) to assist with maintaining continuity of supply
throughout the hospital to local connection points for
eventual introduction into the human body. The device
controls the gas pressure within the specification as
required by the MGPS. In all cases other devices outside
of this scope are connected downstream of the MGPS
are required to control the final gas pressure and flow
requirements for safe supply to the patient. Therefore,
this device is not intended to control supply parameter
hazards directly to the patient, only to the MGPS.
The device including Cylinder Manifold System and
Manifold Changeover System (abbreviate as manifold
below) is principally designed for use as a primary or
secondary source of supply, or for emergency backup.
The Medical Gas Supply System supplies one of the
following medical gases to a piped distribution system,
O2, He, CO2O2, O2CO2, HeO2, O2He, ISO N2O, ISO Inst.
Air, and ISO Med.
8
See Figure 1 for general arrangement and Figure 2 for
the schematic diagram.
10
The Manifold Changeover System consists of:
12
No. Description
1
1
Stage Pressure Regulator
st
2
2
2
Stage Pressure Regulator
nd
3
Smart Box
25
4
Line Bleed Valve
5
Touch Screen Controller
14
6
Vent Valve
15
7
Line Relief Valve Vent Pipe Connector
1
8
Line Source Isolation Valve
9
Line Relief Valve
10
Service Valve
17
11
Line Pressure Gauge
12
Line Isolation Valve
18
13
Intermediate Relief Valve
14
Intermediate Isolation Valve (Three Way)
15
Bank Bleed Valve
16
Intermediate Pressure Gauge
17
Cylinder Gauge
18
Changeover Pressure Sensor
19
Dome Regulator (100-180 psi Delivery Pressure
Manifold Only)
6