power output 7A/24÷28VDC
•
wide AC input voltage range 176÷264V
•
high efficiency 85%
•
LED optical signalisation
1. Technical description.
1.1. General description.
The power supply unit is intended for the feeding of alarm system equipments, which require 24V DC supply
voltage and current load I=7A. The design enables simple changing of the output voltage, within the range of 24V÷28V
DC, using a potentiometer. The power supply unit is protected against short-circuit, overload and overvoltage.
1.2. Technical parameters.
Supply voltage
Current consumption
Supply power
Efficiency
Output voltage
Output current
Output current t
AMB
Output current t
AMB
Voltage adjustment range
Ripple voltage
Short-circuit protection SCP
Overload protection OLP
Overvoltage protection OVP
Optical signalisation
Operation conditions
Dimensions (LxWxH)
Net/gross weight
Protection class PN-EN 60950-1:2007
Connectors
Electrical strength of insulation:
- between input (network) circuit and output
circuits of power-supply (I/PO/P)
- between input circuit and PE protection circuit
(I/P-FG)
- between output circuit and PE protection circuit
(O/P-FG)
Insulation resistance:
- between input circuit and output or protection
circuit
Storage temperature
Vibrations and impulse waves during transport
PS 24V/7A enclosed switch mode power supply
Features of the power supply unit:
<30° C
=40° C
PS2002470
Edition: 2 from 25.05.2012
Supersedes edition: 1 from 05.12.2011
•
protections:
•
•
•
•
176 ÷ 264 V AC 50÷60Hz
1,36A@230VAC max.
200W max.
85%
24V DC
7A
7A - see graph 1.
5A - see graph 1.
24 V ÷ 28V DC
150mV p-p max.
electronic, automatic recovery
105-150% of power supply, automatic recovery
U>115% ÷ 135% of the output, isolation
of the output voltage, automatic recovery
green LED – presence of DC voltage
2-nd enviromental class, temperature: -10
relative humidity 20%...90%, without condensation
226 x 115 x 50 [mm]
0,82kg / 0,90kg
I (first) – requires a protective conductor (PE)
power-supply:Φ0,63-2,50 (AWG 22-10)
outputs: Φ0,63-2,50 (AWG 22-10)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
100 MΩ, 500V/DC
-20ºC...+60ºC
according to PN-83/T-42106
1
SCP short-circuit protection
overvoltage OVP
overvoltage protection (AC input)
overload (OLP)
o
o
C÷40
C
EN
Need help?
Do you have a question about the PS2002470 and is the answer not in the manual?