3�10 REMOTE ON / OFF TERMINALS 5 AND 6
For installations where a remote On / Off function is
required an external switch can be used to over ride
the main On / Off switch
pump on or off.
The machine is supplied with a link installed between
terminals 5 and 6 which should be removed and
replaced with an external switching device as indicated.
Terminals in
heat pump
20
Inlet for
exposed cable.
Inlet for
concealed cable.
and power the heat
5
6
5V DC
Remove the two screws from the back of the Remote
Controller.
To check that the installation is correct, set the
temperature on the remote controller to slightly higher
than the pool water. The IPT should run to heat the
pool, immediately if the pump synchronisation is
not in use, or at the next sampling period if pump
synchronisation is in use.
When the external switch contacts are closed the heat
pump will power on and remain operational until the
external contacts are broken.
Customer's external
remote switch
1007929 ISSUE 1