 Common terminal
Terminal
Terminal name
symbol
Contact input common
(sink)
External transistor
common (source)
SD
24 VDC power supply
common
Encoder pulse dividing
output common
24 V encoder power
supply common
External transistor
common (sink)
PC
Contact input common
(source)
24 VDC power supply
Frequency setting
common
5
Analog signal
output common
Open collector output
SE
common
Safety stop input
SIC
terminal common
Safety monitor output
SOC
terminal common
22
PRE-OPERATION INSTRUCTIONS
Terminal function description
Common terminal for the contact input terminal (sink logic).
Connect this terminal to the power supply common terminal of a
transistor output (open collector output) device, such as a programmable
controller, in the source logic to avoid malfunction by undesirable current.
Common terminal for the 24 VDC power supply (terminal PC, terminal
+24).
Isolated from terminals 5 and SE.
Common terminal for the encoder pulse dividing output terminal.
Common terminal for the 24 V encoder power supply terminal (terminal
PG24).
Connect this terminal to the power supply common terminal of a
transistor output (open collector output) device, such as a programmable
controller, in the source logic to avoid malfunction by undesirable current.
Common terminal for contact input terminal (source logic).
Can be used as a 24 VDC 0.1 A power supply.
Common terminal for frequency setting signal (terminal 2 or 1) and
analog output terminal AM. Do not earth (ground).
Common terminal for terminals DO1, DO2, DO3. Isolated from terminals
SD and 5.
Common terminal for terminals S1 and S2.
Common terminal for terminal So (SO).
Rated specification
Power supply voltage
range: 19.2 to 28.8 VDC
Permissible load current:
100 mA