Design and function
MMA welding
5.3
MMA welding
5.3.1
Connecting the electrode holder and workpiece lead
Risk of crushing and burns!
When changing stick electrodes there is a risk of crushing and burns!
•
Wear appropriate and dry protective gloves.
•
Use an insulated pair of tongs to remove the used stick electrode or to move welded work-
pieces.
Electrical voltage at the shielding gas connection!
During MMA welding open circuit voltage is applied at the shielding gas connection
(G¼" connecting nipple).
•
Place yellow insulating cap on the G¼" connection nipple (protects against electrical vol-
tage and dirt).
Item Symbol
1
2
3
4
5
•
Insert the electrode holder plug and workpiece lead into the welding current socket depending on ap-
plication and lock in place by turning to the right. The corresponding polarity will be based on the infor-
mation of the electrode manufacturer on the electrode packaging.
•
Fit yellow protective cap onto G¼" connecting nipple.
42
Description
0
Electrode holder
Connection socket, "-" welding current
Workpiece lead or electrode holder connection
Workpiece
Connection socket for "+" welding current
Electrode holder or workpiece lead connection
Connection thread - G¼"
Shielding gas connection (inlet)
CAUTION
Figure 5-23
099-000188-EW501
10.10.2023