5.4
MMA welding
5.4.1
Connecting the electrode holder and workpiece lead
Risk of crushing and burns!
When changing stick electrodes there is a risk of crushing and burns!
•
Wear appropriate and dry protective gloves.
•
Use an insulated pair of tongs to remove the used stick electrode or to move welded work-
pieces.
Item Symbol
1
2
3
•
Insert the polarity selection plug in the park socket and lock in place by turning to the right.
•
Insert the electrode holder plug and workpiece lead into the welding current socket depending on ap-
plication and lock in place by turning to the right. The corresponding polarity will be based on the infor-
mation of the electrode manufacturer on the electrode packaging.
099-005502-EW501
2.12.2022
Description
0
Polarity selector plug, welding current cable
•
Connect to the park socket.
Electrode holder
Workpiece
CAUTION
Figure 5-50
Design and function
MMA welding
57