Lenovo ThinkSystem SD665-N V3 Manual page 198

Table of Contents

Advertisement

3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter.
4. Reboot the machine and retry to remove the existing virtual disk.
5. If the problem persists, contact technical support.
• FQXPMSR0032I: Removed existing virtual disk successfully.
Severity: Info
User Action:
Information only; no action is required.
• FQXPMUP0001K: The system configuration does not meet the prerequisite
Severity: Warning
User Action:
1. Follow prompts to update the firmware and retry the update.
2. If the problem persists, contact technical support.
• FQXPMUP0002K: The selected packages are not compatible
Severity: Warning
User Action:
1. Follow prompts to update each individual firmware package.
2. If the problem persists, contact technical support.
• FQXPMUP0003K: Unable to obtain the minimum level of UEFI
Severity: Warning
User Action:
1. Restart BMC via supported method and reboot the system.
2. Reflash BMC firmware.
3. Perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
4. If the problem persists, contact technical support.
• FQXPMUP0004K: Unable to obtain the installed version of UEFI
Severity: Warning
User Action:
1. Restart BMC via supported method and reboot the system.
2. Reflash BMC firmware.
3. Perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
4. If the problem persists, contact technical support.
• FQXPMUP0005K: Unable to obtain the installed version of BMC
194
ThinkSystem SD665-N V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

Table of Contents