• FQXSFMA0004N: No system memory has been detected. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Ensure one or more supported DIMMs are installed in the correct population sequence.
2. If the system has light-path then check for any lit DIMM-connector LEDs, and if found, reseat those
DIMMs. Alternatively ( i.e. if light path is not available) the same can be accomplished using XCC GUI.
3. Swap DIMMs between slots when more than one DIMM is available in the system.
4. If the DIMMs have been upgraded just prior to the issue than update uEFI using alternate or minimal
configuration.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
• FQXSFMA0005N: Memory is present within the system but could not be configured. Please verify
that the memory configuration is valid. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Ensure one or more DIMMs are installed in the server.
2. Resolve existing memory errors if they are present.
3. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all
DIMM connectors are enabled using the Setup utility or the OneCLI utility.
4. Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to
the service information for this product.
5. Clear CMOS memory. Note that all firmware settings will revert to the defaults.
6. Reflash UEFI firmware.
7. If the problem persists, collect Service Data logs.
8. Contact Lenovo Support.
• FQXSFMA0006I: [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3].
Severity: Info
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does not have qualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Please contact your Local Sales Representative or Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
• FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
.
149
Chapter 3
UEFI events