Service Information - Graco A Series Instructions-Parts List Manual

Power supply module , dispensing module , fluid meter
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Care Of Fluid
Solenoid
Valves
The solenoid
valve is normally
closed;
foreign
matter
could hold valve open, preventing
it from stopping
fluid
flow.
Before
attempting
to service
the solenoid
valve,
stop
pump and open dispensing
valve controlled
by solenoid
valve to relieve pressure in line, and shut off valve ahead
of solenoid.
To clean solenoid
valve;
unscrew
operator
retaining
nut, remove
operator
and pull piston from body; clean
parts and seat in body and blow air into body to clear
fluid passageways.
See Fig 11.
Put parts back into body and dispense fluid to see if held
open conditiQn
has been corrected
-
if not, replace
solenoid
valve.
NOTE:
Dispense fluid at dispensing
valve controlled
by solenoid
valve cleaned or replaced until all
air is purged from system.
OPERATOR
RETAINING
NUT
7
IN
OUT
I
Fig 11
SERVICE INFORMATION
Listed below
by the assembly
changed
are DELETED,
OLD and NEW parts.
I
ASSEMBLY
PART
REF
PART
NAME
CHANGED
STATUS
NO.
NO.
I
215-411
Series to f3
DELETED
OLD
NEW
OLD
NEW
105-418
Capacitor
176-720
Panel
217-014
Panel Assy
176-72 1
Panel
217-015
Panel Assy
I
215460
OLD
104-210
Switch
Series to B
NEW
13
106-111
Switch
I
I
215-461
OLD
104-210
Switch
Series to B
NEW
13
106-111
Switch
I
INTERCHANGEABILITY
NOTE:
NEW
parts
replace
OLD parts listed directly
above them.
12
307-362

Advertisement

Table of Contents
loading

This manual is also suitable for:

B series215-411215-461215-460215-474215-475

Table of Contents