Operating Instructions for Actuators Type AB with Control Unit
OM-ENGLISH-ABCSC.V1.2-16xx-V2.02-2023.04.27
• Replace seals
• Check all roller bearings and the worm-wheel assembly and replace if necessary.
Check our lubricants table for recommended oils and greases. (10, page 25)
NOTE: Check the cable glands at regular intervals (annually) for tightness of the cables and retighten if neces-
sary.
If the visual inspection (eg. dust or water penetration) indicates that the effectiveness of the Sealing elements
of the cable entry has suffered damage or aging, such elements have to be replaced preferably by using the
original spare parts from the manufacturer of the equipment or through cable entries of comparable quality as
well as the same ex- or IP protection class.

7 Battery Replacement

WARNING: All work on the opened device is only permitted
in a de-energized state. The device must not be switched on
again during work!
WARNING: For explosion-proof actuators, it is necessary
to wait a certain time after switching off before opening the
cover (see Operating Instructions for SMARTCON Control
Units).
In order to be able to maintain the function of the real-time clock as well as the counter readings of the con-
troller even in a de-energized state, it has a button cell battery. The service life of this battery varies depending
on the ambient conditions, and must be replaced if necessary, at the latest as soon as the control unit issues
the relevant warning (see Operating Instructions for SMARTCON Control Units).
For replacement, pry the battery out of the socket using a plastic lever tool. Make sure that the tool is not
placed under the socket, as this may cause damage to the circuit board. Then replace the battery with the
following characteristics:
• Model Number: CR2032
• Electrochemical System: MnO
• Nominal Voltage: 3V
• Rated Capacity: 225mAh

8 Fuses

Depending on the version of the SMARTCON control unit, there are fuses located in the terminal area, the
dimension of the fuse is indicated next to the fuse holder.