Operating Instructions for Actuators Type AB with Control Unit
OM-ENGLISH-ABCSC.V1.2-16xx-V2.02-2023.04.27
• Protect against floor dampness by storing actuators on wooden grating, pallets, mesh boxes or shelves
• Protect the actuators against dust and dirt with plastic foil
• Actuators must be protected against mechanical damage. It is not necessary to open the controller of
the actuator for servicing batteries or similar operations.
• The storage temperature must be between -20°C to +40°C
It is not necessary to open the controller of the actuator for servicing batteries or similar operations.

3.3 Long-term storage

NOTE: If you intend to store the actuator for over 6 months, follow additionally the instructions below:
• The silica gel in the connection compartment must be replaced after 6 months of storage (from date of
delivery from SCHIEBEL's factory in Vienna)
• After replacing the silica gel, brush with glycerine the connection cover seal. Then, carefully close again
the connection compartment
• Coat screw heads and bare spots with neutral grease or long-term corrosion protection
• Renovate damaged paintwork arising from transport, improper storage, or mechanical influences.
WARNING: For explosion-proof actuators it is not allowed to
overlacquer the actuator extensively. According to the stan-
dard, to avoid elecrostatical charge, the maximal thickness of
the varnish is limited with 200 m.
• Wrap the motor (especially the brake motor) with oiled paper.
• Every 6 months. all measures and precautions for long term storage must be checked for effectiveness
and corrosion protection and silica gel renewed.
NOTE: Failure to follow the instructions above may lead to condensation which can damage to the actuator.

4 Installation Instructions

Installation work of any kind of actuator may only be performed by qualified personnel.

4.1 Mechanical Connection

Make sure that the fitting flanges and the actuator flanges match each other, and that the borehole matches
the shaft or, in the case of actuator model "A"(threaded bushing), that the actuator and fitting threads match
each other.
• Grease the spindle.
• Clean all exposed parts which have been coated with anti-corrosive.
• Thoroughly clean the bolting surfaces of the fittings.
• Lightly grease the connecting joints between the actuator and the fittings.
• Place the actuator on the fittings or the gear.
4 Installation Instructions
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ab80Ab100Ab500Ab5Ab8Ab18 ... Show all

Table of Contents