Advertisement

Available languages

Available languages

Quick Links

Capacity
Power (W)
(230 V~)
SWH 20H M2
20 L
SWH 30H M2
30 L
SWH 20H M3
20 L
350/2500
SWH 30H M3
30 L
SWH 20H M4
20 L
SWH 30H M4
30 L
A
2
1
A.1
Main
board
Interface
A.1
A or B
or
C1
B.1
3
Models with ELCB
Connection
(Ø)
½"
D/E
B
2
1
B.1
q
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWH 20H M2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic SWH 20H M2

  • Page 1 Main Connection Capacity board Power (W) (Ø) Interface (230 V~) SWH 20H M2 20 L SWH 30H M2 30 L SWH 20H M3 20 L ½” A or B 350/2500 SWH 30H M3 30 L SWH 20H M4 20 L...
  • Page 2: Product Dimensions

    100mm 300mm 1. Ống nước nóng 1. Hot water outlet pipe 2. Van an toàn 2. Pressure relief valve 3. Funnel 3. Ống dẫn nước xả 4. Van giảm áp - Nên lắp nếu 4. Pressure reducer recommended if pressure > 5 áp nước >...
  • Page 3: General Warnings

    GENERAL WARNINGS This unit can be used by children of not less than 8 years and people with reduced physical, sensory or mental capabilities or without experience or knowledge if they are properly supervised or if the instructions for using the device safely have been given and if the risks are taking into account.
  • Page 4: Installation

    11/ The drain of the pressure relief device must be operated periodically to remove scale deposits and verify that it isn't blocked. 12/ No hydraulic accessory shall be located between the safety device and the cold water inlet. A pressure reducer (not included) is necessary on the main supply when the pressure is greater than 5 bars (0.5 MPa).
  • Page 5: Maintenance

    than the two live wires. Installation must include upstream of the appliance, an all pole cut-out device (contact opening at least 3 mm: fuse, breaker switch). When the water pipes are made of insulating material, the electrical contacts must be protected by a 30 mA earth-leakage breaker conforming to the standards in force. Thermal circuit breaker: All our products are equipped with a thermostat with thermal circuit breaker and manual resetting which cuts off the power supply to the water heater in case of overheating.
  • Page 6  User maintenance: Operate once a month the discharge of the water safety device to prevent scaling and check that it is not blocked. If this is not done, damage may be caused and the guarantee invalidated.  Maintenance by a qualified person: 1/ Remove the scale sludge.
  • Page 7 CẢNH BÁO CHUNG Trẻ nhỏ, người khuyết tật về thể chất/tâm thần/nhận thức hoặc không có kinh nghiệm hoặc không biết cách sử dụng phải được hỗ trợ trong quá trình sử dụng. Không để trẻ em đùa nghịch với thiết bị này. Lau chùi và bảo trì phải do người lớn thực hiện.
  • Page 8 11/ Van an toàn phải được xả định kỳ mỗi tháng, nhằm loại bỏ cặn bị đóng và đảm bảo van không nghẹt. Giúp tăng tuổi thọ & an toàn bình. 12/ Không được lắp thêm phụ kiện nước khác vào đường kết nối giữa thiết bị...
  • Page 9 Bình nước nước phải được kết nối với điện áp 1 pha 220V-240V. Dây dẫn điện sử dụng có tiết diện 2.5mm . Nên sử dụng loại dây dẫn, thiết bị đóng ngắt tiêu chuẩn. Bình nước nóng nên được nối với ELCB chống rò 30mA. Dây tiếp đất có...
  • Page 10 Đối với các điều kiện cụ thể bên ngoài Liên minh châu Âu, vui lòng tham khảo thẻ bảo hành cuả thị trường hiện tại. Tại VIỆT NAM sản phẩm được phân phối bởi: Công ty TNHH GROUPE ATLANTIC VIETNAM 09.17.15.16.16...

This manual is also suitable for:

Swh 30h m2Swh 20h m3Swh 30h m3Swh 20h m4Swh 30h m4

Table of Contents