General View; Hydraulic Circuit - Ferroli 0T3B2HGA Instructions For Use, Installation And Maintenence

Table of Contents

Advertisement

BLUEHELIX PRO RRT 24 C

4.2 General view

196
350
34
16
35
42
241
14
44
fig. 55- General view

4.3 Hydraulic circuit

35
34
42
14
10
8
fig. 56- Hydraulic circuit
EN
186
193
114
36
39
32
241
136
37
74
9
11
cod. 3541T010 - Rev. 00 - 10/2019
14
Safety valve
191
16
Fan
32
Heating circulating pump
34
Heating temperature sensor
35
Air separator
56
36
Automatic air vent
42
DHW temperature probe
44
Gas valve
81
56
Expansion vessel
81
Ionization/ignition electrode
186
114
Water pressure switch
136
Flowmeter
145
Water gauge
186
Return sensor
191
Fume temperature sensor
193
Trap
196
Condensate tray
241
Bypass
136
350
Fan/Burner assembly
193
36
114
32
145
8
Domestic hot water outlet
9
Cold water inlet
10
System delivery
11
System return
14
Safety valve
32
Heating circulating pump
34
Heating temperature sensor
35
Air separator
36
Automatic air vent
37
System water inlet filter
39
Flow limiter
42
DHW temperature probe
56
Expansion vessel
74
System filling faucet
114
Water pressure switch
136
Flowmeter
186
Return sensor
56
193
Trap
241
Automatic bypass (inside the pump
unit)
43