Table. 7- THROTTLE position and parameter setting
Gas family
Gas type
G20
nd
2
G31
rd
3
fig. 31
Checking the combustion values
MAKE SURE THE FRONT CASING IS CLOSED AND THE FLUE SYSTEM IS CORRECTLY ASSEMBLED & IN-
STALLED TO THE CURRENT REGULATIONS.
1. Put the boiler in heating or DHW mode for at least 2 minutes. During this period if the flame symbol flashes on the
display, it means that the boiler is performing a calibration. Wait until the flame becomes steady (end of calibration).
2. Activate the TEST mode (see "TEST mode activation" on page 24).
3. With the boiler working at maximum and then minimum output, connect a calibrated electronic combustion analyser,
to the flue gas sampling point on the appliance conector, check that the CO2 content in the flue, matches that given
in the below table.
Combustion Values
A
New boiler (first ignition/conversion or electrode replacement)
B
Boiler with at least 500 hours of operation
4. If the combustion values do not match, perform the 100% calibration as described in the following paragraph.
5. Value A: if the values still do not match, do not activate other calibrations, as the system needs to work longer to be
able to self-adapt.
6. Value B: if the values still do not match yet, proceed with activation of the parameter SC12 or SC13, depending on
the type of adjustment necessary (see ""Sc" - Combustion Control Parameters Menu" on page 28)
22
BLUEHELIX PRO RRT 24 C
Throttle position
cod. 3541T010 - Rev. 00 - 10/2019
Parameter setting
1
2
1
2
fig. 32
G20
G31
7.5%-9.9%
9%-11.5%
9%+/-0.8
10%+/-0.8
nA
LP
1
2
EN