DIVATOP D F

4.2 General view and main components

16
278
22
95
194
114
42
5
Sealed chamber
7
Gas inlet - Ø 3/4"
8
DHW outlet - Ø 1/2"
9
DHW inlet - Ø 1/2"
10
System flow - Ø 3/4"
11
System return - Ø 3/4"
14
Safety valve
16
Fan
19
Combustion chamber
22
Burner
27
Exchanger
28
Fume manifold
32
Circulating pump
36
Automatic air vent
37
Cold water inlet filter
42
DHW temperature sensor
EN
364
43
5
10
8
44
fig. 42- General view - DIVATOP D F32
cod. 3542B970 - Rev. 02 - 09/2023
7
9
11
136
74
37
32
43
Air pressure switch
44
Gas valve
56
Expansion vessel
74
System filling faucet
81
Ignition and detection electrode
95
Diverter valve
114 Water pressure switch
136 Flowmeter
145 Pressure gauge
194 DHW exchanger
241 Automatic bypass
278 Double sensor (Safety + heating)
364 Anti-condensation fitting
28
27
19
56
81
14
36
145
80