Element4 Trisore 140 User And Installation Manual

Three-sided modern direct vent gas fireplace
Hide thumbs Also See for Trisore 140:

Advertisement

Quick Links

Gebruikers- en installatie handleiding (NL/BE)
User- and installation manual
Trisore 140, Bidore 140, Modore 140,
Trisore 140, Bidore 140, Modore 140,
Trisore 95, Bidore 95, Modore 95,
Trisore 95, Bidore 95, Modore 95,
Trisore 70, Bidore 70, Modore 70.
Trisore 70, Bidore 70, Modore 70.
WARNING - THE COMBUSTION CHAMBER OF THIS STOVE SHOULD
ONLY BE OPENED AND SERVICED BY A REGISTERED GAS INSTALLER
(i.e. GAS SAFE REGISTERED ENGINEER[GB])
Let op: de verbrandingskamer van deze gashaard mag uitsluitend
worden geopend en onderhouden door een bekwaam gasinstallateur
Laat deze instructies als handleiding achter bij het toestel
These instructions should be left with the customer for future reference

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Trisore 140 and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 Trisore 140

  • Page 1 Gebruikers- en installatie handleiding (NL/BE) User- and installation manual Trisore 140, Bidore 140, Modore 140, Trisore 140, Bidore 140, Modore 140, Trisore 95, Bidore 95, Modore 95, Trisore 95, Bidore 95, Modore 95, Trisore 70, Bidore 70, Modore 70. Trisore 70, Bidore 70, Modore 70.
  • Page 2: Table Of Contents

    This Manual Covers the following appliances: Trisore 140, Bidore 140, Modore 140, Trisore 95, Bidore 95, Modore 95, Trisore 70, Bidore 70, Modore 70. Contents GENERAL INFORMATION......................3 Important Safety Notice .........................3 General Fitting Information ....................4 USER INFORMATION........................5 Remote Control Electronic Ignition System RCE GV60 ...............5 INSTALLER INFORMATION..............
  • Page 3: General Information

    GENERAL INFORMATION Important Safety Notice ing regulations. It is therefore recommend that a registered gas installer be employed for this task. The engineer will provide you with informa- This appliance has a ceramic Fire-bed arrange- tion about the safety limits of the installation and ment;...
  • Page 4: General Fitting Information

    GENERAL INFORMATION General Fitting Information ment of the Environment, the Building Standards (Scotland) (Consolidation) Regulations issued by Inlet pipe connection 8mm compression the Scottish Development Department. Chimney requirements Balanced Flue Flue monitor Permanent Pilot BS 5440 part 1, BS 5871 part 2 and BS 6891. User control: Variable rotary control inc.
  • Page 5: User Information

    USER INFORMATION USER INFORMATION Remote control electronic ignition - temperature display in degrees Celsius or Remote control electronic ignition sys- - temperature display in degrees Celsius or system RCE GV60 Fahrenheit; tem RCE GV60 Fahrenheit; - time; - time; - thermostat function; The appliance is supplied with a remote control.
  • Page 6 USER INFORMATION USER INFORMATION USER INFORMATION MAN position I g n i t e t h e a p p l i a n c e a s f o l l o w s ; MAN position I g n i t e t h e a p p l i a n c e a s f o l l o w s ;...
  • Page 7 USER INFORMATION Time Flame height / standby The flame height can be adjusted continuously by The display can indicate time. After placing the battery or simultaneously press- using the buttons (large flame) and By continuing to lower the flame height, the ap- (small flame), the time indication will flash on the pliance can be set to the standby position;...
  • Page 8 USER INFORMATION Example Timer for thermostat function By using the Y TEMP function you can keep the Using the timer enables you to set two times per day temperature at 20 °C; while 24 hours for switching on the day temperature you use the 4 TEMP function at night to maintain and two times per 24 hours for switching on the a temperature of 15 °C.
  • Page 9 USER INFORMATION Replacing the battery Setting times for the timer To set the timer, proceed as follows: If the battery is almost empty, the display will show “BATT”. Set the day and night temperature as described above Briefly press the SET button to enter the (P*) To replace the battery, proceed as follows: Remove the cover at the back side of the TIMER position.
  • Page 10: Installer Information

    INSTALLER INFORMATION the supplier, thus the appliance must only be nstallatIon installed with the original flue system, no others Before beginning the installation, check that the may be used details on the rating plate correspond to the gas type and pressure to which the appliance will be The gas fire, in combination with the concentric connected.
  • Page 11 INSTALLER INFORMATION This appliance has adjustable legs, these must Note: A covered passageway should not be me set to stabalise the fire before flue position is treated as a carport. Flues should not be sited in finalised. a covered passageway between properties. Do not make any adjustments to the appliance, Basements,Lightwells and Retaining except the leg length.
  • Page 12: Terminal Locations Wall Mounting

    INSTALLER INFORMATION INSTALLER INFORMATION Terminal Locations Wall Mounting Terminal Locations Wall Mounting Dimension Terminal Position Distance (mm) Dimension Terminal Position Distance (mm) Directly below an opening,air brick, opening window etc. Directly below an opening,air brick, opening window etc. Above an opening,air brick, opening window etc. Above an opening,air brick, opening window etc.
  • Page 13: Terminal Locations Roof Termination

    INSTALLER INFORMATION Terminal Locations Roof Termination “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A ventilation opening serving an occupied room, a toilet or a bathroom A heating air supply, when the supply flows through an occupied room. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
  • Page 14: Concentric Flue Parts Identification

    INSTALLER INFORMATION Concentric Flue Parts Identification The following pages identify the parts that may be used in the Balanced Flue installation of this appliance. The Item number in the table refers to the item number of the part in the Identification pages, this Item number is also the number that will be used to identify parts in the Installation suggestion diagrams.
  • Page 15 INSTALLER INFORMATION INSTALLER INFORMATION...
  • Page 16 INSTALLER INFORMATION INSTALLER INFORMATION...
  • Page 17 INSTALLER INFORMATION INSTALLER INFORMATION...
  • Page 18 INSTALLER INFORMATION INSTALLER INFORMATION...
  • Page 19 INSTALLER INFORMATION INSTALLER INFORMATION USVK 100 130 REDUCER Ø130 - Ø100 USDHC 130 HORIZONTAL TERMINALØ130...
  • Page 20 INSTALLER INFORMATION INSTALLER INFORMATION USBI 100 130 Elbow 90° with inspection cover USI 100 130 Inspection Element...
  • Page 21: Rigid Balanced Flue Connection Possibilities

    Maximum vertical height “V” whilst using a wall terminal: 3 meter Maximum vertical height “V” whilst using a wall terminal: 3 meter Horizontal possibilities Modore95/Bidore95/Trisore95: Horizontal possibilities Trisore 140/ Bidore 140/ Modore 140: 0,5 meter vertical gives maximum horizontal 2 meter 0,5 meter vertical gives maximum horizontal 0,5 meter...
  • Page 22: Vertical Roof Terminations

    INSTALLER INFORMATION Vertical Roof Terminations When installing the appliance with a roof termination (classification 31) it is important to fit a flue restrictor across the flue outlet inside the fire. Roof terminations will need the 60 mm flue restrictors fitting. This is delivered with the fire. We recommend using flue reducer USVK to flue dimension 150/100...
  • Page 23 INSTALLER INFORMATION INSTALLER INFORMATION Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150/100.
  • Page 24 INSTALLER INFORMATION INSTALLER INFORMATION Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150/100.
  • Page 25: Installing Remote Control Electronic Ignition System Gv60

    INSTALLER INFORMATION Installing the controls Electronic Ignition System RCE GV60) This requires no external electrical power to operate. The receiver unit has only one lead. This lead has one single plug. This plug fits into the connector block on the front of the Gas Control unit, the orientation of this plug is important.
  • Page 26: Arranging The Ceramic Fire-Bed

    slots on the Burner Tube. The Pilot flame must be visible through the grate and the d. Make sure there is a 1 cm gap between the back log and the back wall of the fire. INSTALLER INFORMATION INSTALLER INFORMATION Log Arrangements - Trisore 95, Bidore 95 &...
  • Page 27 s sitting firmly in the base of the fire box, with the long slot in the centre of the Grate e slots on the Burner Tube. The Pilot flame must be visible through the grate and the INSTALLER INFORMATION INSTALLER INFORMATION eld.
  • Page 28 INSTALLER INFORMATION INSTALLER INFORMATION IMPORTANT NOTICE FOR ALL LOG ARRANGEMENTS: IMPORTANT NOTICE FOR ALL LOG ARRANGEMENTS: Ensure that a number of holes in the grate and the Pilot area are free of embers. Ensure that a number of holes in the grate and the Pilot area are free of embers. Finally check the pilot is clear, no embers have entered the Pilot area and the Finally check the pilot is clear, no embers have entered the Pilot area and the cross lighting is good before the glass is replaced.
  • Page 29 INSTALLER INFORMATION INSTALLER INFORMATION Log Arrangements - Trisore 140, Bidore 140 Log set LSE412 Log Arrangements - Trisore 140, Bidore 140 Log set LSE412 Only the ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown Only the ceramics supplied with this appliance are to be used.
  • Page 30 INSTALLER INFORMATION INSTALLER INFORMATION...
  • Page 31: Gravel Arrangements

    Gravel Arrangements / Blackstones / Commissioning the appliance Brilliants INSTALLER INFORMATION Ensure that the Grate , is sitting firmly in the base A soundness test MUST be made before the of the fire box, with the long slot in the centre of installed stove is left with the customer.
  • Page 32: Installing The Fire

    PORTANT INSTALLATION TIPS FALSE CHIMNEY BREAST: INSTALLER INFORMATION The false chimney breast must always be constructed of an non-combustible material; Always ventilate the space above the appliance by means of grills or a comparable INSTALLATION TIPS alternative with a minimum air supply of 200 cm2; For the finish, use special stucco (min 100 degrees C resistant) or glass fibre wallpaper Please read first the general fitting information which one can find on page 4 of this booklet.
  • Page 33 INSTALLER INFORMATION INSTALLER INFORMATION INSTALLER INFORMATION INSTALLER INFORMATION INSTALLATION OF THE GLASS WINDOW INSTALLATION OF THE GLASS WINDOW INSTALLATION OF THE GLASS WINDOW INSTALLATION OF THE GLASS WINDOW Remove the window trims left, right and bottom like shown in figure 1, 2, 3 Remove the window trims left, right and bottom like shown in figure 1, 2, 3 Remove the window trims left, right and bottom like shown in figure 1, 2, 3 Remove the window trims left, right and bottom like shown in figure 1, 2, 3...
  • Page 34: Servicing Instructions

    SERVICING INFORMATION SERVICING INFORMATION Troubleshooting servicing instructions Troubleshooting servicing instructions On the next pages you will find remedies for The following outlines only the minimum work that On the next pages you will find remedies for The following outlines only the minimum work problems which may accur when using fires should be performed on an annual basis.
  • Page 35: Troubleshooting

    TROUBLE SHOOTING "Problem” "Possible cause” "Remedy” A. No transmission 1. The (new) communication code 1. Hold down the reset button of the receiver, until you hear a long beep between receiver and remote control (motor will not run) . Let go of the reset button after the must still be confirmed.
  • Page 36 TROUBLE SHOOTING “Problem” “Possible cause” “Remedy” F. Electronics keep sparking while the 1. Receiver is damaged. 1. Replace the receiver and confirm the code pilot burner is ignited (remedy 1 at A) 1.1 Measure the voltage, using a 1. Thermocouple does not function. G.
  • Page 37: Technical Information

    TECHNICAL INFORMATION Technical drawings Modore 70 Bidore 70...
  • Page 38 TECHNICAL INFORMATION Trisore 70 Modore 95 1052...
  • Page 39 TECHNICAL INFORMATION Trisore 95 1024 Bidore 95 1001...
  • Page 40 TECHNICAL INFORMATION Modore 140 1418 1414 1376 1388 1518 Bidore 140 1471 1385 1388 1419 1434...
  • Page 41 TECHNICAL INFORMATION Trisore 140 1464 1400 1464 1460 1388 1494...
  • Page 42: Technical Details

    TECHNICAL INFORMATION Countries of Destination The following table gives detail of the Countries that these appliances are approved for use within. The tables following immediately on give the technical characteristics of the appliances. Natural Austria I2H G20@20mbar ü Belgium I2E+ G20/G25@20/25mbar ü...
  • Page 43 TECHNICAL INFORMATION Austria ü I3B/P G30/G31@50mbar Belgium ü I3+ G30/G31@28-30/37mbar CH Switzerland ü I3B/P G30/G31@50mbar, I3+ G30/G31@28-30/37mbar CY Cyprus ü I3B/P G30/G31@30mbar Czech Republic ü I3B/P G30/G31@50mbar, I3+ G30/G31@28-30/37mbar DE Germany ü I3B/P G30/G31@50mbar DK Denmark ü I3B/P G30/G31@30mbar Estonia ü...
  • Page 44 Type: Trisore 95, Bidore 95, Trisore 70, Bidore 70, Modore 70, Trisore 140, Bidore 140 Product: atmospheric gas heating appliance Applicable EEC directives: 90/396/EEC Type: Trisore 95, Bidore 95, Modore 95, Trisore 70, Bidore 70, Modore 70, Trisore 140, Bidore Applied harmonized standards: NEN-EN-613 140, Modore 140...
  • Page 45 TECHNICAL INFORMATION TECHNICAL INFORMATION PIN : 0359CN1268 PIN : 0359CN1268 Modore 140...
  • Page 46: Warranty

    Warranty The warranty for your Element4 appliance will be provided by your supplier. In case of com- plaints, you must always contact him. Your supplier will contact Element4 if necessary. The factory warranty is valid for 24 months after date of purchase.
  • Page 48 Element4 B.V. Paxtonstraat 23 8013 RP Zwolle September 2014 The Netherlands...

Table of Contents