Oki MC760 Maintenance Manual page 156

Hide thumbs Also See for MC760:
Table of Contents

Advertisement

Error code
Cause
C468
The backup
roller
C466
thermistor
Does this error recur?
has detected
an abnormal
Does this error recur?
temperature
(high
temperature
or low
temperature.)
C56A
Option unit
I/F error
C56B
(C56A=Duplex
Does this error recur?
C56C
Unit,
C56D
C56B=2nd Tray,
Does this error recur?
C56C=3rd Tray
C56D=4th Tray)
C56E
When LCF is setting,Tray2 Unit
I/F Error or Tray3 Unit I/F Error
is report from PU.
Interchange the error to LCF
Unit I/F Error by CU.
Occur:When communication
has dropped off.
C91D
RFID Reader
RFID read device error
not Installed
Does this error recur?
C91A
RFID reader
Interface error with the RFID
I/F error
reader is detected.
C91B
01: Communication error
C91C
02: Error in the wireless circuit
03: Communication error
04: Error is detected in the RFID
Error details
Remedial measure
Turn on the power
again.
Yes
Replace the fuser
unit.
Yes
Replace the low
voltage power
supply unit.
Turn on the power
again.
Yes
Check for sure
connection of the
connectors.
Yes
Replace the option
unit.
Turn on the power
again.
Yes
Check for normal
connection of the
RFID R/W board.
Yes
Replace the RFID
R/W. Replace the
PU board.
01: Same as the
error no. C91D
02: Replace the
between the RFID reader
RFID R/W
and the engine circuit
board.
boards.
03: Check for
normal
of the RFID reader
connection of
the antenna
cable.
between the RFID reader
and the toner cartridge.
04: Check if
quantity of the
toner cartridge
toner cartridge.
is correct or
(In more than 4)
not.
Error code
Cause
C37A~
Abnormal
Is the cable from belt thermistor
C37D
temperature
to the high voltage board
of belt
connected normally?
C37A: Short-
Does this error recur?
circuit
C37B: Open
circuit
C37C: High
temperature
C37D: Low
temperature
C020
Image drum
The ID does not rotate normally.
lock error
Does the error display recur
when the power is turned off
once and back on?
C4E3
Fuser motor
Fuser does not rotate normally.
lock error
Does this error recur?
C4FA
Media
Media has wrapped around the
wrapped
fuser.
around the
fuser error
C5B2
Tray-2/3/4
C5B2=2nd Tray
C5B3
CPU clock
C5B3=3rd Tray
C5B4
frequency
C5B4=4th Tray
error
C5B5
When LCF is setting, Tray2
Clock Adjust Error or Tray3
Clock Adjust Error is report from
PU.
Interchange the error to LCF
Clock Adjust Error by CU.
F041
Over than
Over than available setting
available
number tray is installed.
setting
number tray
detection
error
7. Troubleshooting and repair procedure
Error details
Remedial measure
No
Re-connect the
cables normally.
Yes
Turn on the power
again.
No
Replace the belt
thermistsor.
Check if the ID is
installed normally
or not.
Yes
Replace the ID
unit.
Yes
Replace the ID
motor.
Check if the
fuser is installed
normally or not.
Yes
Replace the fuser.
Yes
Replace the fuser
motor.
Turn off the power.
Replace the fuser.
Replace the Tray
board GOH-11.
Replace the Tray
board
Remove the
available setting
number tray.
156 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc770Mc780Es7470mfpEs7480mfp

Table of Contents