This procedure is to be used to calibrate the TSCM and PBCM proofer humidity reading if
the factory calibration labeling is unavailable for the humidity sensor and measurement
equipment is not available.
temperature (61⁰F to 80⁰F).
To access the Actual Oven
Humidity, first press the
This screen will appear.
Press the factory button.
Use keypad to Enter Pin Code
"9898". Press .
CAUTION:
WARNING for CA residents: go to www.dukemfg.com/prop65 for prop 65 warning
Begin the process with the unit setup and ready to operate and room
Press
button.
When Sensor Calibration screen
is displayed, use
change the humidity setting.
Press
Please read these instructions completely before attempting
to install, operate or service this equipment.
This manual is Copyright © 2020 Duke Manufacturing Co. All rights reserved.
Reproduction without written permission is prohibited. Duke is a registered
trademark of the Duke Manufacturing Co.

Humidity Calibration

TSCM & PBCM
or
to
to exit.
Instruction Sheet
Visual Guidelines
Fogged= 70%RH @105⁰F
Droplets= 75%RH @105⁰F
Droplets running=
80%RH @105⁰F
REV A 07/20/2020
P/N 523103

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSCM and is the answer not in the manual?

Questions and answers

Summary of Contents for Duke TSCM

  • Page 1 Instruction Sheet Humidity Calibration TSCM & PBCM This procedure is to be used to calibrate the TSCM and PBCM proofer humidity reading if the factory calibration labeling is unavailable for the humidity sensor and measurement equipment is not available. Begin the process with the unit setup and ready to operate and room temperature (61⁰F to 80⁰F).
  • Page 2 105 ºF and water droplets just starting to run down the inside surface of the proofer door glass. Droplets running= 80%RH @105⁰F Phone: 314-231-1130 Duke Manufacturing Co. Toll Free: 1-800-735-3853 2305 N. Broadway www.dukemfg.com Fax: 314-231-5074 St. Louis, MO 63102...

This manual is also suitable for:

Pbcm

Table of Contents