2.1

Personnel

The fan may only be used by qualified, instructed and trained personnel. The persons must know the relevant safety di-
rectives in order to recognise and to avoid risks. The individual activities and qualifications can be found in Table 1 Qual-
ifications, page 2.
Table 1 Qualifications
Activities
Storage, operation, transport, cleaning, disposal
Electrical connection, commissioning, electrical
disconnection
Installation, disassembly
Maintenance
Repair
Note:
The operator is responsible for ensuring that personnel are instructed and have understood the contents of
the operating instructions. If something is unclear, please contact Systemair or its representative.
2.2

Personal protective equipment

♦ Wear protective equipment during all work in the vicinity of the fan.
• protective working clothes
• protective working shoes
2.3

5 rules of electrical safety

1. Disconnect (disconnection of
the electrical system from
live components at all
terminals)
3
Warranty
For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance
with the data sheets and manual. Further prerequisites are a completed maintenance plan with no gaps and a commis-
sioning report. Systemair will require these in the case of a warranty claim. The commissioning report is a component
of this document. The maintenance plan must be created by the operator, see section 11.2 Maintenance.
4

Delivery, transport, storage

Safety information
Warning: Risk from rotating fan blades
♦ Prevent access by unauthorised persons by safety personnel or access protection.
Warning: Suspended loads
♦ Wear protective equipment during all work in the vicinity of the fan, details see 2.2 Personal protective equipment,
page 2.
♦ Do not walk under suspended loads.
♦ Make sure that there is nobody under a suspended load.
Qualifications
Trained personnel (see following note)
Electrical expert or matching qualification
Fitter or matching qualification
Electrical expert or matching
qualification
Electrical expert or matching
qualification
Smoke extraction fans and EX fans only by agreement with
Systemair.
• protective working gloves
• helmet
2. Prevent reactivation
3. Test absence of voltage
Fitter or matching
qualification
Fitter or matching
qualification
• goggles
• hearing protection
4. Ground and short-circuit
5. Cover or restrict adjacent live parts