Description Of Alarms - Ravelli Easy 12 C Use And Maintenance Manual

Table of Contents

Advertisement

Description of alarms

AL
Warning
AL 01 BLACK - OUT
AL 02 SMOKE SENSOR
AL 03 HOT SMOKE
AL 04 FAN BROKEN
AL 05 NO IGNITION
AL 06 NO PELLETS
THERMAL
AL 07
ALARM WITH
RESET
AL 08 DEPRESSION
AL 11
LOW FLAME
AL 12 FAN RPM
AUGER PHASE
AL 14
AUGER TRIAC
AL 15
To reset the alarm, keep the OK key pressed for a few seconds. The stove can be restarted manually or automatically (in the case
of an active chronothermostat or external thermostat) only after resetting the alarm.
Use and maintenance manual Easy 12 C
Reason
No electricity supply during working phase
The smoke sensor is malfunctioning
The smoke sensor has been disconnected from
the board
Combustion in the fire pot is not optimal
The centrifugal fan is defective
Smoke extractor encoder is not functioning or not
correctly connected
No electricity supply to smoke extractor
The smoke extractor is blocked
The pellet tank is empty.
Setting of pellets and of intake during ignition
phase insufficient.
The resistance for lighting is defective of not in
position
The pellet tank is empty
The ratiomotor does not load pellets.
No pellet loading
The thermostat with manual reset has intervened
The centrifugal fan is defective
Combustion in the fire pot is not optimal
The combustion chamber is dirty
The flue is blocked
The vacuum switch is malfunctioning
The pellet tank is empty.
Bad setting of pellet and air on ignition in phase
The revolution of smoke fan lowering more the
15% of speed to fan congestion
The gear motor is not correctly connected
The device in the motherboard who gears the
auger is defect
Solution
Press the off button and repeat switching on the
stove
If the problem continues, contact the area Techni-
cal Assistance Centre.
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
Switch off the stove, clean the fire pot and regu-
late combustion with the setting of the pellets.
Contact local Technical Assistance Centre.
If the problem continues, contact the area Techni-
cal Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Check if there are pellets inside the tank.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Check whether there are pellets in the tank
Empty the tank to check that no objects have
fallen inside which could prevent the correct func-
tioning of the auger
Regulate the pellet setting
If the problem continues, contact the area Techni-
cal Assistance Centre.
Reset the thermostat pressing the button on the
back of the stove
Please contact local Technical Assistance Centre.
Switch off the stove, clean the fire pot and regu-
late combustion with the setting of the pellets.
If the problem continues, contact the area Techni-
cal Assistance Centre.
Follow the cleaning operations of the stove as per
the instructions in the booklet
Check that the flue is clear and clean
Please contact local Technical Assistance Centre
Check whether there are pellets in the tank
Contact local Technical Assistance Centre
Contact local Technical Assistance Centre
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
EN
Rev.0 23/03/2023
Pag.39