Ravelli AURORA CANALIZZATA User And Maintenance Manual

Ravelli AURORA CANALIZZATA User And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

IT MANUALE D'USO E MANUTENZIONE
PER MODELLI CON TECNOLOGIA RDS
(Per modelli con scheda FLASH)
EN USER AND MAINTENANCE MANUAL
FOR STOVES WITH RDS TECHNOLOGY
(For model with FLASH memory card)
FR MANUEL D'EMPLOI EST ENTRETIEN
POUR POÊLES AVEC TECHNOLOGIE RDS
(Pour modèles avec carte electronique FLASH)
DE PELLETHEIZÖFEN MIT RDS TECHNOLOGIE
GEBRAUCHS- UND WARTUNGSANLEITUNG
(für Modelle mit FLASH-Platine)
ES MANUAL D'UTILIZACION Y MANUTENCION
MODELOS CON TECNOLOGIA RDS
(Para modelos con fi cha FLASH)
DK BRUGER - OG VEDLIGEHOLDELSESMANUAL
FOR PILLEOVNE MED RDS TEKNOLOGI
(Til modeller med FLASH bundkort)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AURORA CANALIZZATA and is the answer not in the manual?

Questions and answers

Philippe Bour
February 14, 2025

Bonjour. Je possède un poele ravelli auro glass canalizzata , je crois que mon débitmètre est hs, quel débitmètre je dois mettre? Cordialement.

Subscribe to Our Youtube Channel

Summary of Contents for Ravelli AURORA CANALIZZATA

  • Page 1 IT MANUALE D’USO E MANUTENZIONE DE PELLETHEIZÖFEN MIT RDS TECHNOLOGIE PER MODELLI CON TECNOLOGIA RDS GEBRAUCHS- UND WARTUNGSANLEITUNG (Per modelli con scheda FLASH) (für Modelle mit FLASH-Platine) EN USER AND MAINTENANCE MANUAL ES MANUAL D’UTILIZACION Y MANUTENCION FOR STOVES WITH RDS TECHNOLOGY MODELOS CON TECNOLOGIA RDS (For model with FLASH memory card) (Para modelos con fi...
  • Page 2: Table Of Contents

    75% Palazzolo sull’Oglio Ravelli srl Ravelli srl - Via Kupfer, 31 - 25036 Palazzolo sull’Oglio - BS - ITALY Tel. 030.7402939 - www.ravelligroup.it Table of contents Thank you Pag.
  • Page 3: Thank You Pag

    As already mentioned earlier, pellets with a diameter of 6 mm must With the Ravelli stove, you will see that quality and economy can go hand be used with the stove. However. it may also operate with pellets...
  • Page 4: Spare Parts

    The combustion if fine and no ad. The picture 3 show a flame done with a stove Ravelli recommends using a pellet with a diameter of 6 mm for the stove. Otherwise it will be necessary to ask the assistance centre for working at power P5.
  • Page 5: Positioning, Assembly And Installation

    12.5 0.016 The data shown above are indicative and not binding. Ravelli reserves the right to make any modifications for the purpose of improving the performances of the product. For This type of installation (see Fig. 9) requires an insulated flue, as all the any information related to the dimention and weigth of the stove, please refer to the smoke pipe has been installed outside the house.
  • Page 6 In the lower part of the flue, a union tee has been mounted with an inspection cap. A 90° bend should not be installed as the first initial piece as the ashes would quickly obstruct the passage of smoke, causing problems for the draught of the flue.
  • Page 7: Description Of The Controls And Simbology Of The Display

    CONDITIONS CAN ONLY BE RESOLVED WITH AN APPROPRIATE SETTING OF THE EXTERNAL THERMOSTAT MODE STOVE BY RAVELLI APPROVED TECHNICAL PERSONNEL. if you use an external thermostat correctly connected as shown in the electrical scheme ( reference paragraph 10), the display will not show the 7.
  • Page 8: Set Of The Working Power

    7.1.3. set of the working power this menu press 3 times the key OK after having selected the icon with the writing “Stove To modify the working power press status”. This menu is used both by the after sale center to understand the reason of the key 2 to enter in the dedicated malfunctioning of the stove and by the end user as well for the pellet loading in the tank.
  • Page 9: Menù "Language

    1 and 2. By last con- hours, it is just a setting made dur- fi rmation with OK you save all settings ing the tests we make in Ravelli, and return automatically to the screen before the stoves are packed and with the icons.
  • Page 10: Comfort Clima

    8.2. Comfort clima ENTER IN THE MENU PRESS KEY OK TO To enter in the USER MENU press two times key OK. “STOVE STATUS” ACTIVATE THE SCREW To enter in the menu “COMFORT CLIMA” press 6 times key 2 and con- firm with OK.
  • Page 11: Cleaning The Fire Pot

    10.1. Certificate of Guarantee Ravelli thanks you for the confidence you have placed in it with the purchase of one of our pellet stoves and invites the purchaser to: •...
  • Page 12: Description Of Alarms

    11. DESCRIPTION OF ALARMS WARNING REASON SOLVING • The pellet tank is empty • Check whether there are pellets in the tank • The ratiomotor does not load • Empty the tank to check that no objects have fallen inside which could prevent the PELLETS FINISHED pellets.
  • Page 13: Electric Wiring Diagrams

    12. The electrical wiring diagram Pag.26...
  • Page 14 à 75%. Palazzolo sull’Oglio Ravelli srl Ravelli srl - Via Kupfer, 31 - 25036 Palazzolo sull’Oglio - BS - ITALY Tel. 030.7402939 - www.ravelligroup.it SOMMAIRE Page 28 Remerciement 7.2.7...
  • Page 15: Remerciement

    Description du manuel d’emploi et entretien : tien doivent être exécutés par du personnel qualifié et autorisé. Avec ce manuel d’emploi et entretien, la société Ravelli désire fournir à l’utilisateur toutes • Des erreurs d’installation ou un mauvais entretien (non conformes à ce qui les informations sur la sécurité...
  • Page 16: Pièces De Rechange

    Pour l’emploi dans les poêles, Ravelli vous conseille un granulé de 6 mm de diamètre. Combustion idéale qui ne nécessite pas des modifica- En cas différent il faudra demander l’intervention du centre d’assistance pour faire tions.
  • Page 17: Positionnement, Montage Et Installation

    Les données indiquées ci-dessus sont communiquées à titre indicatif, elles ne sont pas contraignantes. Ravelli se réserve la faculté de faire n’importe quelle modifi cation dans le but d‘améliorer les Ce type d’installation (Voir Fig. 9) a besoin d’un conduit de fumée calorifugé, car tout le performances des produits.
  • Page 18 Dans la partie inférieure du conduit de fumée on a monté un raccord de type “T” avec bouchon d’inspection. Il est déconseillé d’installer comme première pièce initiale une courbe à 90°, car la cendre boucherait en peu de temps le passage des fumées, en causant des problèmes au tirage du poêle.
  • Page 19: Description Des Commandes

    Sonde Consolle, si on utilise cette modalité, doit être sélectionné par la touche 2 et DE FUMEES. EN CAS DE CONDITIONS PRECAIRES, LE SEUL REMEDE CONSISTE confi rmé avec la touche OK. A CONTACTER LES TECHNICIENS AUTORISES D’Ravelli, POUR EFFECTUER UN REGLAGE ADEQUAT DU POELE. MODALITE’ THERMOSTAT EXTERNE Dans le cas où...
  • Page 20: Programmation Puissance Du Travail

    7.1.3 Programmation puissance du travail menu est utilisé soit par le S.A.V. pour comprendre quel est le mauvais fonctionnement du Pour modifi er la puissance du travail, ap- poêle, que par l’utilisateur au moment du chargement des granulés de bois dans la trémie. Fig.
  • Page 21: Menu "Langue

    en supposant en plus que l’utilisateur veuille programmer une température ambiant 7.2.10 Menu “VOIR TARAGES“ de 21°C, et que pour atteindre cette température il programme la puissance du tra- vail à 3. Les passages à effectuer seront les suivants : Dans ce menu on pourra vérifi...
  • Page 22: Comfort Clima

    11. Entretien), d’un nettoyage extraordinaire à effectuer avec l’aide d’un installa- QU’IL Y A DES PROBLEMS DE COMBUSTION ET EST CONVENABLE teur (agrée par Ravelli). CONTACTER LE C.A.T. (CENTRE D’ASSISTANCE TECNICQUE). Au moment de l’installation du poêle l’operateur programmera un numéro d’heures travail convenable au model choisi.
  • Page 23: Nettoyage Des Surfaces

    10.1. Certificat de garantie des écaillages de la porte, ainsi que l’impossibilité d’allumer le poêle. Ravelli vous remercie de la confiance que vous nous avez accordée en achetant notre poêle à granulés, et invite l’acheteur à: • lire les instructions d’installation, d’emploi et d’entretien du poêle.
  • Page 24: Description Des Alarmes

    11. DESCRIPTION DES ALARMES SIGNALISATION RAISON SOLUTION Le réservoir des granulés est vide Vérifi er s’il y a des granulés dans le réservoir Vider le réservoir pour vérifi er si des objets sont tombés à l’intérieur, ce qui pourrait em- ALARME GRANULÉS Le motoréducteur ne charge pas les granulés pêcher à...
  • Page 25: Le Schéma Électrique

    12. SCHÉMA ÉLECTRIQUE Pag.38...
  • Page 26 Ravelli does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice.

Table of Contents

Save PDF