Description Of Alarms - Ravelli AURORA CANALIZZATA User And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

11. DESCRIPTION OF ALARMS

WARNING
REASON
• The pellet tank is empty
• The ratiomotor does not load
PELLETS FINISHED
pellets.
ALARM
• No pellet loading
• No electricity supply during working phase
BLACK - OUT
• The pellet tank is empty.
• Setting of pellets and of intake during ignition phase insufficient.
NO IGNITION ALARM
• The resistance for lighting is defective or not in position
• The pellet tank is empty.
ALARM LOW FLAME
• Bad setting of pellet and air on ignition phase
• The revolution of smoke fan lowering morenthe 15% of speed to fan
ALARM FAN RPM
congestion
• Smoke extractor encoder is not functioning or not correctly connected • Contact local Technical Assistance Centre.
• No electricity supply to smoke extractor
ALARM FAN BROKEN
• The smoke extractor is blocked
• The combustion chamber is dirty
• The flue is blocked
DEPRESSION ALARM
• The vacuum switch is malfunctioning
• The thermostat with manual reset has intervened
• The centrifugal fan is defective
THERMAL ALARM WITH
RESET
• Combustion in the fire pot is not optimal
• Combustion in the fire pot is not optimal
ALARM SOVRATEMP FUMI
• The centrifugal fan is defective
The smoke sensor is malfunctioning
The smoke sensor has been disconnected from the board
SMOKE SENSOR ALARM
• The door and the ashtray are not corectly closed
ALARM
• Bad combustion in the fire pot
INSUFFICIENT
FLOW
Presence of a foreign object inside the inlet air
• The device who read the quantity of inlet air could be dirty and so not
ALARM SPORCO
DEBIMETRO
read correctly
ALARM GUASTO
• The device could be disconnected or defect
DEBIMETRO
ALARM
• The gear motor is not correctly connected
FASE COCLEA
ALARM
•The device in the motherboard who gears the screw is defect
TRIAC COCLEA
By pressing the button P3 on the display. the alarm can be reset.
Try and repeat lighting after the cooling phase.
Unscrew the protection cap and press the
button to reset the thermostat alarm.
SOLVING
• Check whether there are pellets in the tank
• Empty the tank to check that no objects have fallen inside which could prevent the
correct functioning of the screw
• Regulate the pellet setting
• If the problem continues, contact the area Technical Assistance Centre.
• Press the off button and repeat switching on the stove
• If the problem continues, contact the area Technical Assistance Centre.
• Check if there are pellets inside the tank.
• Contact local Technical Assistance Centre.
• Contact local Technical Assistance Centre.
• Ceckis pellet is in the hopper
• Contact local Technical Assistance Centre.
• Contact local Technical Assistance Centre.
• Contact local Technical Assistance Centre.
• Contact local Technical Assistance Centre.
• Follow the cleaning operations of the stove as per the instructions in the booklet
• Check that the flue is clear and clean
• Contact local Technical Assistance Centre.
• Reset the thermostat pressing the button on the back of the stove (see Fig. below).
• Contact local Technical Assistance Centre.
• Switch off the stove, clean the fi re pot and regulate combustion with the setting of the pellets.
• If the problem continues, contact the area Technical Assistance Centre.
• Switch off the stove, clean the fi re pot and regulate combustion with the setting of the pellets.
• Please contact the local Technical Assistance Centre
• If the problem continues, contact the area Technical Assistance Centre.
• Please contact the local Technical Assistance Centre
• Please contact the local Technical Assistance Centre
• If the problem continues, contact the area Technical Assistance Centre.
• Check the devices are closed
• Switch off the stove, clean the fire pot, the grid and set the combustion through the set
pellet/flow.
• Check for and remove unwanted object
• Please contact the local Technical Assistance Centre
• Please contact the local Technical Assistance Centre
• Please contact the local Technical Assistance Centre
• Please contact the local Technical Assistance Centre
• Please contact the local Technical Assistance Centre
Pag.25